Loading...
HomeMy WebLinkAbout902 Ridge Runner Dr - Applications/Single Family New - 02/18/20144 City of II COMMUNITY DEVELOPMENT & NEIGHBORHOOD For t Collins 281 N. College Ave. • Fort Collins, CO 80522-0580 • Phone: 970-221-6760 www.fcgov.com/building BUILDING PERMIT APPLICATION APPLICATION NUMBER / bO t ` J APPLICATION DATE ' �2 ' �U Q' /(/ Job Site Address q 0,1 W lAcpP� 'I u vl n eY far. Unit # PROPERTY OWNER INFO: (All ownerinformationis required - it is not optional) Phone # Last name�S��1t� �� �t 6Aa75 first Name Middle n � Street Address�i I VL�.�r it State W Zip %-" r_r� CONTRACTOR INFO: Company Name ntractor Phone # 3 b� -U c� -� S 7 y Lic Holder Name i Ckci r C1 PA t-% S k City of Fort Collins License #b- joq I Supervisor Cert # r a Mailing Address 0 C"he-1414City I I) I Ac 5y tr State �Zip LEGAL INFO: \ W I4 rt Subdivision/PUDT ; ,� . ` 1)-tcx C1 Filing # Lot # Block #�� Lot Sq Ft 7 r5 . . CONSTRUCTION INFO: Total Building Sq Ft (not including basement) k5g y SF Total Garage Sq FtF- Residential Sq Ft Comm'I Sq Ft # of Stories_ Bldg Height # Dwelling Units 15' Floor Sq Ft _ Ci & e, g. 2nd Floor Sq Ft (12jq5 S.. 31d Floor Sq Ft Unfiished Bsmt Sq Ft R4!� R,+F Finished Bsmt Sq Ft # of Bedrooms 3 # of Full Baths �2-/. Baths Yz Baths I # of Fireplaces Air Conditioning: Ye No Energy info: ( Circle appropriate choice) 1. ComCheck 2. ResCheck w/Air Sealing 3. ResCheck w/Blower Door 4. Simulated Performance Alternative 5. Prescriptive w/Air Sealing 6. Prescriptive w/ Blower Door City of Fort Collins Stock Plan # List appropriate option #s UTILITIES INFO: LAN Water Tap Size '1 1% t( Sewer Tap Size A Metered Ye)or No Temp. Pedesta(o or No Type of Heat: §&Gas ❑ Electric Electric Main Breaker Size (Residential only) ❑ 150 Amp or Less ❑ 200 Amp ❑ Other Value of Construction (including IaborLmaterial & profit) Contact Name & Phone # of JOBSITE SUPERVISOR: Qe i i n lea yxgP w�% I D" NCO- l 1 L) I Subcontractor Info: Electrical S10Ng; 'V% E4grk i C. Mechanical Plumbing T.P I iUef 1'i4/riArp Framer Roofing Concrete Fireplace Solar Nfl Other Other Other Applicant: I hereby acknowledge that I have read this application and state that the above information is correct and agree to comply with all requirements contained herein and City of Fo Ilins ordina es and state laws regulating building construction. a p� ` ? ,y� Applicant Signature �� rint Name rl . o �4 MJC�Ir /�l[6�F'hone d C % aiZ % ° V Distribution: White - Office Yellow - Applicant Pink - WWW/Stormwater THIS APPLICATION EXPIRES 180 DAYS FROM APPLICATION DATE City of - P/annina..Devpinnment & Transportation Services F6r_ Y ,development &Neighborhood Services — �A — -U � 281North ollege Avenue Fort Collins, 3 970.4116.2740 i Building Permit Application Submittal Requirements for New Single Family Residential Construction (& Additions) (Revised 12-3-2010) The items listed below shall be included in all new requests for building permit. Please initial in front of the item indicating that it is included in the submittal. Only complete submittals will be reviewed. Current adopted code is 2009 IRC. Initial Required Item ✓ Building Permit Application — Three-part form to be completed by applicant. Plan Check Fee - (See www.fcgov.com or obtain Fee Schedule at B & Z counter) Two copies of everything listed below. For Building review. Additional 3rd set if building is over 50 years old or older For Historical review Site Plans - Architectural site plan, drawn to scale on 8'/2"A 1" sheet showing the location of the building relative to property lines and other structures on the lot. Architectural Drawings - Architectural drawings showing all floor plans, elevations, stair section, (� building section, and wall section detailing all construction components used. Drawings must be drawn to scale such as 1/4"= V-0". Structural Drawings (floor framing & roof framing) —Structural documents bearing an original seal and signature of an architect or engineer registered in the State of Colorado. Structural drawings, shall include all beams, floor system, roof system, spans, posts, columns, hangers and connections, and locate and identify all point loads. Plans shall verify that the design meets the following criteria: Wind Ioad=100 MPH exposure B, 30-LB roof/snow live load and 15-LB dead load. Wall Brace Design — Plan showing "Brace Wall' locations and method of construction. If the house does not meet the prescriptive brace requirements of 2009 IRC section R602.10, engineered design bearing a seal and signature of an architect or engineer registered in the State of Colorado is required. Engineered Foundation — Foundation documents bearing an original seal and signature of an architect or engineer registered in the State of Colorado. The design requirements shall be for a 30" LZ frost dept, seismic zone (1) and 30-LB snow load. Identify wet or damp-proof requirements. Identify and size subsurface drainage system. Energy Code - (Two Copies) Submit the Fort Collins Energy Code Compliance Form. If SPA method is selected, preliminary rating must be submitted also. Additions must comply with prescriptive energy code, see the Fort Collins Energy Compliance Form. HVAC sizing & load calculations - (Two Copies) Code section M1401.3 requires the HVAC system be designed based on loads calculated from ACCA manual J, 81h or current edition. Duct sizing must be included designed per ACCA manual D. See local amendment N1101.1 for Thermal Design. Parameters. Not required for additions. Other - Include construction, utility, value of construction, description of work and subcontractor information. Applications must be signed by the applicant and must include a daytime phone number. Grading Plan may be required if new impervious area is over 350 sq ft. Contact Stormwater Development Review at 970-221-6700 for more information. Applicant Name Telephone Number Job Site Address