Loading...
HomeMy WebLinkAbout829 Brookedge Dr - Disclosures/Blower Door Test - 03/18/2014BUILDING LEAKAGE TEST Date of Test: 03/18/2014 Technician: Michael Chavez Test File: Shadow Creek Blower Door Customer: Shadow Creek Homes Building Address: 829 Brookedge Drive 7600 E. Orchard Road Fort Collins, CO 80525 Greenwood Village, Colorado 80111 Phone Test Results 1. Airflow at 50 Pascals (50 Pa = 0.2 w.c.) 2. Leakage Areas: 1154 CFM (+/- 0.1 %) 2.65 ACH 0.46 CFM per ft2 floor area 277.5 in2 (+/ 1.4 %) Canadian EgLA @ 10 Pa 238.7in2(+/ 2.2 %) LBL ELA @ 4 Pa 3. Minneapolis Leakage Ratio: 0.17 CFM50 per ft2 surface area 4. Building Leakage Curve: Flow Coefficient (C) = 708.2 ( +/- 3.3 %) Exponent (n) = 0.125 ( +/- 0.008 ) Correlation Coefficient = 0.99352 5. Test Settings: Test Standard: = CGSB Test Mode: = Depressurization Equipment = Model 3 Minneapolis Blower Door Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: 3. Recommended Whole Building Mechanical 55.0 CFM Ventilation Rate: (based on ASHRAE 62.2) Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: BUILDING LEAKAGE TEST Page 2 Date of Test: 03/18/2014 Test File: Shadow Creek Blower Door Building Conditions Inside Temperature: Outside Temperature: # of Stories Wind Shield: # of Occupants # of Bedrooms: Volume: Surface Area: Floor Area: Design Winter Wind Speed: Design Summer Wind Speed: Comments 70 deg F Heating Fuel: 61 deg F Heating Fuel Cost: 1.0 Heating Efficiency: Heating Degree Days: M Cooling Fuel Cost: Cooling SEER: Cooling Degree Days: 3.0 26102 ft3 Ventilation Weather Factor: 6915 ft2 Energy Climate Factor: 2500 ft2 GARAGE W RT HOUSE: 48 Pa @ 50 Pa Design Winter Temp Diff: Design Summer Temp Diff: Gas BUILDING LEAKAGE TEST Page 3 Date of Test: 03/18/2014 Test File: Shadow Creek Blower Door Data Points: Data Entered Manually Nominal Temperature Building Fan Pressure Nominal Adjusted Fan Baseline Pressure (Pa) (Pa) Flow Flow % Error Configuration Sid Dev (Pa) -0.4 n/a +/- 0.00 -65.0 43.8 1200 1190 -0.2 Ring A -60.0 43.0 1190 1180 -0.0 Ring A -55.0 42.3 1180 1170 0.2 Ring A -50.0 41.2 1165 1155 0.2 Ring A -45.0 39.7 1145 1135 -0.2 Ring A BURGESS FEE]] CONMWnON CONSULTANTS INC. 5LWki u AIR LEAKAGE REPORT Date: March 19, 2014 Rating No.: 03231237 DE Building Name: Plan 1595 Rating Org.: Burgess Inc. Owner's Name: Shadow Creek Homes Phone No.: 303-300-4527 Property: 829 Brookedge Drive Rater's Name: Robert Hutchinson Address: Fort Collins, CO 80525 Rater's No.: 7479033 Builder's Name: Shadow Creek Homes Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 829 Brookedge Dr.blg Rating Date: 03/18/2014 Whole House Infiltration Duct Leakage Ventilation Blower door test Heating Cooling Natural ACH: 0.12 0.10 ACH @ 50 Pascals: 2.68 2.68 CFM @ 25 Pascals: 742 742 CFM @ 50 Pascals: 1165 1165 Eff. Leakage Area: [sq.in] 64.0 64.0 Specific Leakage Area: 0.000181 0.00018 ELAM00 sf shell: [sq.in] 0.921 0.92 Leakage to Outside Units Hvac CFM @ 25 Pascals: 0 CFM25 / CFMfan: 0.0000 CFM25 /CFA: 0.0000 CFM per Std 152: N/A CFM per Std 152 / CFA: N/A CFM @ 50 Pascals: 0 Eff. Leakage Area: [sq.in] 0.00 Thermal Efficiency: N/A Total Duct Leakage Units CFM25/CFA Total Duct Leakage: 0.0380 Mechanical: Exhaust Only Sensible Recovery Eff. (%): 0.0 Total Recovery Eff. (%): 0.0 Rate (cfm): 61 Hours/Day: 24.0 Fan Watts: 11.3 Cooling Ventilation: Natural Ventilation ASHRAE 62.2 - 2010 Ventilation Requirements For this home to comply with ASHRAE Standard 62.2 - 2010 Ventilation and Acceptable Indoor Air Quality in Low -Rise Residential Buildings, a minimum of 55 cfm of mechanical ventilation must be provided continuously, 24 hours per day. Alternatively, an intermittently operating mechanical ventilation system may be used if the ventilation rate is adjusted accordingly. For example, a 110 cfm mechanical ventilation system would need to operate 12 hours per day, as long as the system operates to provide required average ventilation once each hour. REM/Rate - Residential Energy Analysis and Rating Software 04.4.1 This information does not constitute any warranty of energy cost or savings. ©1985-2014 Architectural Energy Corporation, Boulder, Colorado.