Loading...
HomeMy WebLinkAbout2326 Trestle Rd - Disclosures/Blower Door Test - 02/13/2014BUILDING LEAKAGE TEST Date of Test: 2/13/2014 Test File: Bartran Homes 2326 Trestle Rd BD Customer: Bartran Homes Technician: Paul Higman Project Number: Fort Collins, CO Building Address: 2326 Trestle Rd Fort Collins, CO 80525 Test Results 1. Airflow at 50 Pascals: 1304 CFM50 (+/- 0.6 %) (50 Pa = 0.2 w.c.) 2.20 ACH50 0.3272 CFM50/ft2 floor area 2. Leakage Areas: 207.2 in2 (+/- 2.1 %) Canadian EgLA @ 10 Pa 141.0 in2 (+/- 3.5 %) LBL ELA @ 4 Pa 3. Building Leakage Curve: Flow Coefficient (C) = 292.6 ( +/- 5.5 %) Exponent (n) = 0.382 ( +/- 0.015 ) Correlation Coefficient = 0.99464 4. Test Settings: Test Standard: CGSB Test Mode: Depressurization Infiltration Estimates 1. Estimated Average Annual Infiltration Rate: 2. Estimated Design Infiltration Rate: Cost Estimates 1. Estimated Cost of Air Leakage for Heating: 2. Estimated Cost of Air Leakage for Cooling: n 144.7 CFM 0.24 ACH Winter: 233.3 CFM Summer: 154.9 CFM 0.39 ACH 0.26 ACH Digitally signed by: Paul P�n,I Higman j DN: CN = Paul Higma ,.i anC=US D e: 2014.04.10 15:29:13-06'00' BUILDING LEAKAGE TEST Page 2 of 4 Date of Test: 2/13/2014 Test File: Bartran Homes 2326 Trestle Rd BD Building Information Location Climate Information Volume 36610 Surface Area Floor Area 3986 Height 18 # of Bedrooms 5 # of Occupants Year of Construction 2013 Wind Shield M Heating and Cooling Cost and Efficiency Information Heating Fuel Gas Heating Fuel Cost Heating Efficiency % Cooling Fuel Cost Cooling SEER Ventilation Weather Factor 0.87 Energy Climate Factor 17.00 Heating Degree Days 6128 Cooling Degree Days 297 Design Winter Wind Speed 7.3 mph Design Summer Wind Speed 1 9.4 mph Design Winter Temp Diff 73 deg F Design Summer Temp Diff 15 deg F Equipment Information Type Manufacturer Model Serial Number Custom Calibration Date Fan Energy Conservatory Model 3 (110V) Default Micromanometer Energy Conservatory DG700 BUILDING LEAKAGE TEST Page 3 of 4 Date of Test: 2/13/2014 Test File: Bartran Homes 2326 Trestle Rd BD Depressurization Test: Environmental Data Indoor Temperature(A°F) Outdoor Temperature(A°F) 63.0 28.0 Data Points-Data Entered Manually Nominal Baseline Adjusted Fan Nominal Adjusted Building Pressure Building Pressure Pressure Flow Flow Fan (Pa) (Pa) (Pa) (cfm) (cfm) % Error Configuration -2.1 n/a n/a -61.2 -59.2 62.3 1425 1376 -1.1 Ring A -55.4 -53.4 58.4 1381 1334 -0.3 Ring A -50.1 -48.1 53.7 1326 1281 -0.3 Ring A -45.4 -43.4 50.9 1292 1248 1.0 Ring A -40.4 -38.4 47.3 1247 1205 2.1 Ring A -35.1 -33.1 41.4 1168 1128 1.3 Ring A -30.1 -28.1 34.7 1072 1035 -1.1 Ring A -25.5 -23.5 29.0 982 949 -3.0 Ring A -20.5 -18.5 247.5 931 899 0.8 Ring B -1.9 n/a n/a Deviations from Standard CGSB-Test Parameters - n value(0.382)outside of acceptable limits. BUILDING LEAKAGE TEST Page 4 of 4 Date of Test: 2/13/2014 Test File: Bartran Homes 2326 Trestle Rd BD Comments House WRT Garage east=-48.5pa House WRT Garage south=-47.6pa ( CI�Of �Ort` C��� Planning, Development & Transportation Services /"`� Community Development& Neighborhood Services Simulated Performance Alternative (SPA) Cover Sheet Submittal and Rating Type ❑Stock Plan Permit—Projected Worst-Case Rating Builder Model: ❑Lot-specific Permit-Projected Rating Address: ❑� Completed,Home—Confirmed Rating Aad�eSs: 2326 Trestle Rd Data Required for All SPA Ratings Builder: Bartran Homes Rating Firm: GS SeNIC@S Ener9Y rater: Paul Higman Date: 2-13-14 Duct Location In uts Location Su I Return °/a Area R-Value %Area R-Value All within conditioned space 100 0 100 0 Utilit Rates Ener Source Service char e Rate Electricity 5 $/month 0.10 $/kWh Natural gas �5 $/month 0.60 $/therm Spaces considered outside the thermal boundary: Additional Information for Stock Plan Permit— Projected Worst-Case Rating "Worst-case"configuration: Foundation type(s) Options included Orientation of front elevation Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report Attach REM/Rate Energy Code Inspection Checklist Additional Information for Lot-Specific Permit— Projected Rating �ttach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report ttach REM/Rate Energy Code Inspection Checklist Additional Information for Completed Home— Confirmed Rating �Attach REM/Rate Fort Collins 2012 Annual Energy Cost Compliance report (Utility rates reflected in this report must be City-approved rates on lot-specific permit application date.) �Attach Home Energy Rating Certificate Updated 11/09/2012