HomeMy WebLinkAbout2557 Maple Hill Dr - Disclosures/Final Energy - 04/25/2014Fort Collins Energy Cost Complianu�
€,.3 { Electric
`e, - s f € : ems., t-
Property
Organization
Journey Homes
GS Services
2557 Maple Hill Dr
970-449-1612
Fort Collins, CO 80524
Paul Higman
Weather:Ft. Collins, CO Builder
2557 Maple Hill Dr Journey Homes
Journey Homes 2557 Maple Hill Dr
Annual Energy Cost
FC 2012
$/yr
As Designed
Heating
402
40
Cooling
` 81
6
Water Heating
378- ,- '-
37
SubTotal - Used to'.Determine lCompliance
861
84
Lights Et Appliances -
709
�70
Photovoltaics
0.
Service Charge-
240.. `. sE
24
Total
1810'
179
Mandatory Requirements
Window'U-Factor Check (Section 402.5): ,
Window U-Factor'(,Design must be equal -or lower)0.400 0
HomeInfiltration (Section 402.A.2j°' PAS
Duct leakage (Section'403.2.2):` PAS
This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code,
amended by the City of Fort Collins. In fact, this home surpasses the requirements by 1.6%.
Name Paul Higman Signature
Organization GS Services Date 25 April 2014
Digitallq--sigtt d
Haul by:,Paul Higman
Mechanical Systems DN` CN-=-Paul
Heating Fuel=fe_ed air distribution__, 73_J kBtuh, 92__.1 AFUE. `
i
Cooling Air conditioner, 30.0 kBtuh &n C US
uu 13.0 SEER. g
H i g m a i pate: 2014.04.25
Water,Heating Conventional, Elec, 0.95 EF: Jff
Window -to -Floor Area Ratio: 0.10 <' // 0 :25.30-06?001
Blower door test Htg: 1426 Clg: 1426 CFM50
In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to
calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the
design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained
periodically to ensure the compliance calculations reflect current federal minimum standards.
REM/Design - Residential Energy Analysis Software v14.4.1
This information does not constitute any warranty of energy cost or savings.