Loading...
HomeMy WebLinkAbout2038 Kerry Hill Rd - Disclosures/Final Energy - 03/12/20145 awn R" & AWW DR Horton lq4�7x_ 2038 Kerry Hill Dr AV Ft Collins, CO 80525 energyLogic> > > > t 4 n+E1trB byA# •i. nvavuerurtarpyto�ta,aou 5 Stars Plus Confirmed Uniform Energy Rating System Energy Efficient 1 Star 1 Star Plus 2 Stars 2 Stars Plus 3 Stars 3 Stars Plus 4 Stars 1 4 Stars Plus 5 Stars 5 Stars Plus 500-401 400-301 300-251 250-201 200-151 150-101 100-91 90-86 85-71 70 or Less HERS Index: 59 Conditioned Area: 6445 sq. ft. Conditioned Volume: 63734 cubic ft. HouseType: Single-family detached Foundation: Conditioned basement Bedrooms: 5 Mechanical Systems Features Water Heating: Conventional, Natural gas, 0.59 EF, 50.0 Gal. Heating: Fuel -fired air distribution, Natural gas, 92.1 AFUE. Cooling: Air conditioner, Electric, 13.0 SEER. Duct Leakage to Outside: 220.00 CFM25. Ventilation System: Exhaust Only: 109 cfm, 15.0 watts. Programmable Thermostat Heafing: Yes Cooling: Yes Ceiling Flat: R-38.0 Slab: R-0.0 Edge, R-0.0 Under Sealed Attic: NA Exposed Floor: R-38.0 Vaulted Ceiling: NA Window Type: U-Value: 0.300, SHGC: 0.300 Above Grade Walls: R-21.0 Infiltration Rate: Htg: 2826 Clg: 2826 CFM50 Foundation Walls: R-11.0 Method: Blower door test fi�,y���--•'aau ryirsua n.c rcaauca ;.' ._ n v_�.,.�..-..�'`'�'� ".m- ad+�.'��w�^a� �c:� k« "�'-�?��a•'` �..+i �».....u'__= _ �:-3 Percent Interior Lighting: 97.00 Range/Oven Fuel. Electric Percent Garage Lighting: 100.00 Clothes Dryer Fuel: Electric Refrigerator (kWh/yr): 696.00 Clothes Dryer EF: 3.01 Dishwasher Energy Factor: 0.00 Ceiling Fan (cfmNVatt): 0.00 The Home Energy Rating Standard Disclosure for this home is available from the rating provider. REM/Rate - Residential Energy Analysis and Rating Software v14.4 This information does not constitute any warranty of energy cost or savings. ©1985-2013Architectural Energy Corporation, Boulder, Colorado. Registry ID: 736709511 Rating Number: 30580 Certified Energy Rater: Tyler Stein Rating Date: 03/12/14 Rating Ordered For: DR Horton Homeowner Estimated Annual Energy Cost Confirmed Use MMBtu Cost Percent Heating 113.7 $771 31% Cooling 3.5 $102 4% Hot Water 26.5 $159 6% Lights/Appliances 41.2 $1206 49% Photovoltaics -0.0 $-0 -0% Service Charges $240 10% Total 184.8 $2478 100% This home meets or exceeds the minimum criteria for all of the following: ASHRAE Standard 90.2 -1992 2004 International Energy Conservation Code 2006 International Energy Conservation Code 2009 International Energy Conservation Code Home Energy Rating Provider Energy Logic, Inc, P.O. Box N Berthoud, CO 80513 Phone # 1-800-315-0459 No:'tD9&069J°/Ai www.nrglogia/com aRlairAtioN Certified Energy Rater ��Mp�xowp` � NE 4 (DnergyLogic a Se-9osoen}` C analysts. Insight. answers. ��eomwn°� FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT Date: March 12, 2014 Rating No.: 30580 Building Name: DR Horton Rating Org.: EnergyLogic, Inc Owner's Name: DR Horton Homeowner Phone No.: (970) 556-0839 Property: 2038 Kerry Hill Or Rater's Name: Tyler Stein Address: Ft Collins, CO80525 Rater'sNo.: 9951760 Builder's Name: DR Horton Weather Site: Ft. Collins, CO Rating Type: Confirmed File Name: 2038 Kerry Hill Or DR Horton REM.bIg Rating Date: 03/12/14 Annual Energy Cost ($) FC 2012 As Designed Heating: 954 901 Cooling: 219 140 Water Heating: 158 158 SubTotal - Used to Determine Compliance: 1332 1199 Lights &Appliances: 1236 1206 Photovoltaics: -0 -0 Service Charge: 240 240 Total: 2808 2645 Mandatory Requirements: Duct Insulation R-Value Check (per Section 405.2) Minimum Duct Insulation (Design must be equal or higher) 6.0 8.0 Window U-Factor Check (Section 402.5) Window U-Factor (Design must be equal or lower): 0.400 0.304 Home Infiltration (Section 402.4.2): PASSES Duct Leakage (Section 403.2.2): PASSES This home MEETS the annual energy cost requirements of Section 405 of the 2009 International Energy Conservation Code, amended by the City of Fort Collins. In fact, this home surpasses the requirements by 9.9%. Name: Tyler Stein Signature: Organization: EnergyLogic, Inc Date: Marcf; 2, 2014 REM/Rate - Residential Energy Analysis and Rating Software v14.4 This information does not constitute any warranty of energy cost or savings. ©1985-2013Architectural Energy Corporation, Boulder, Colorado. FORT COLLINS 2012 ANNUAL ENERGY COST COMPLIANCE - NON -ELECTRIC -HEAT DR Horton Page 2 Design energy cost is based on the following systems: Water Heating: Conventional, Gas, 0.59 EF. Heating: Fuel -fired air distribution, 56.0 kBtuh, 92.1 AFUE. Cooling:Airconditioner, 30.0 kBtuh, 13.0 SEER. Heating: Fuel -fired air distribution, 56.0 kBtuh, 92.1 AFUE. Cooling:Air conditioner, 24.0 kBtuh, 13.0 SEER. Window -to -Floor Area Ratio: 0.09 Blower door test: Htg: 2826 Clg: 2826 CFM50 In accordance with IECC, building inputs, such as setpoints, infiltration rates, and window shading may have been changed prior to calculating annual energy cost. Furthermore, the standard reference design HVAC system efficiencies are set equal to those in the design home as specified in the 2009 IECC. These standards are subject to change, and software updates should be obtained periodically to ensure the compliance calculations reflect current federal minimum standards. REM/Rate - Residential Energy Analysis and Rating Software v14.4 This information does not constitute any warranty of energy cost or savings. 01985-2013 Architectural Energy Corporation, Boulder, Colorado.