Loading...
HomeMy WebLinkAbout400 Jackson St - Special Inspections/Backflow - 12/09/2010DEC-18-2010 22:42 From: 12/16/2010 18:43 97022GIO79 To:2246134 FARBER LAWN SERVICE Page:2,2 PAGE 01/01 MICHAEL RUSNAK (HOMEOWNER) Test Date/Time: Guage Serial * District Required Info: Tester Certification #: 1723 pate Certification Expries: Assembly Test Results: U PASS LJ FAIL S cicflow Prevention Device Test & Maintenance Report 1-1-Aeo ndnr and mihmit rmmnfeted mnv within 10 devs of the test) -Water District/Authority: Ctry o t F t olIins Account: Contact Person: Facilfty Name: Contact Phone: Service Address: 400 JAC SON STREET FT COLLINS, S CO 80521 Mailing Address: Same at3 above Owner ❑ Manager Conhadar tither ontaCtPerson: JOE SULLIVAN Company Namefiitle: ARCHER HOMES Contact Phone: 227-7588 -Mailing Address: 4020 BINGHAM HILL ROAD FT COLLINS, CO 80521 -Make: FEBCO o e: 7 5 rze- _.•, Type: ❑ RPZ ❑ DC PVB El ❑ t�p ❑ AVG ❑ Other Device Date Installed: 12/M010 Location on Property. South Side of House ❑ taa�n�n p�„ t� Orientation Service rotectiop. "pueviousdevice sa"# Inlet Outlet: ❑ Domestic ❑ containment, ❑ Vertical up ❑ ❑ Fire ❑ I9olatlon New Insta►latim ❑ Vertical Down ❑ O Irrigation Containment by Iso121ion ❑ Stolen ❑ Horizontal ✓❑ ❑ Other Line PSI: Initial Test Results, Repaired: eaned: ❑ ck*l ❑ Ck#2 ❑ RV jOckat ❑ at,#2 ❑ Rv e4"t Results 40# Ti htness Differential Ti htness Differential Check Valve #1 RPZ, Dc, PVe SVB Leak R right 1.8 t/t#f ❑ Oise ❑ riny ❑seat ❑ other: ❑ Leak ❑ Tight _ Check Valve 92 ❑ Leak Ck#2 ❑ Leak RPZ, OC Tight El disc Elsprf seat El other- t Relief Valve RV RV, RPZ ❑ Diaphragm ❑ seat ❑ omer. Buffer epaired: Cleaned: RPZ ❑ Air Inlet Q Air Inlet Air Inlet Air inlet, PV8, SV8 2.8 Air Inlet 1 ❑ DoDDet Obonnet ❑ other; Shutoff Valve #1 Leak Ti tit 50V #1: O n u Artivat 0 n at Departure Beckpress�re exists? YES tip cause Shutoff Valve #2 1 El leak Tight SOV #2:U open uaon Arrival U Opm At Departure •;Assembly Concerns Test Procedure: Comments: eZ (only if applicable) '. ❑ InoNred InSmllation ❑ ABPA p ASSE �❑ Inconea Use Tum off date: Tum off date: I `Tum off time: ITUM oft t1m2: Alarm ompany ire Department Notified: In Person Notified: Contacted by: EW Turn off date/time: Turn on dateltime: est a t e:: Watts Model: TK99E Last Calibration Daw 01/142010 i hereby wo y mat the iso @swb&u off VaMes (SO V e1 and sov a2) Aare bm renrme0 b ure POWW In wnrcn they name fWad and mar the rest teat wee cone sctmwv to - rAd prooedumA dio" Above r Woad byte Water Dlsfict/Au1R*V &W rA &boar) MOM teat i­-7dfiga are hue and Wcw= CD Me bat Of aW NY- �` (pkam pdno (p(ees® pfou Testing Company: Farber Lawn SVC Phone 308-5031 Customer Name: MICHAEL RUSNAK Phone WOWsa Pori() Tester Name: Mark FartJer Tester Signature: /%% a. vstorner&anmre: tiaCKnow s are who tesTor repair assemblics on a fire line Must Do MqLstereO YAtI1 the o ore o ivision o ire a e .