TOTAL ENGINEERING SERVICE, INC
1601 37n' ST EVANS COLORADO 80620 970-330 1071 FAX 970 330 1252
May 4 2010
Mr Adam Luckeroth
WC Builders
P O Box 200307
Evans CO 80620
Re 3174 Lower Loop Dr
Trail Head Subdivision L13 B 11
Fort Collins
Dear Mr Luckeroth
It is the understanding of Total Engineering Service Inc that each end of the double
1 / x 11 7/8 LVL floor beam located on the north side of the above referenced single family
residence is bearing directly on the concrete in each beam pocket This is not acceptable as it
creates a potential for decay and rot of the bottom of the beam due to accumulation of
moisture As such Total Engineering Service Inc recommends that the bottom of the beam
at each end should be separated from the concrete with (1) layer of sill sealer foam matenal
and steel shims The bottom of the beam should be notched no more 1 to allow for
placement of the foam & shims
Please contact me if you have any questions concerning this matter
Sincerely
TOTAL ENGINEERING SERVICE INC
QkJO Ur
6fy
Howard Davison P E c,4�� r 0A,
Project Engineer r�el;Af^f0�s