Loading...
HomeMy WebLinkAbout2803 Saddle Creek Dr - Special Inspections/Engineering - 05/24/2011f, 5'j• PROGRESSIVE ENGINEERING &c CONSULTING, LLC 404 IMMIGRANT TRAIL WINDSOR, CO 80550 (970) 590-6059 May 24, 2011 Hawkstone Builders '7251 W. 20' Street, Suite D1 Greeley, CO 80550 RE: 2803 Saddle Creek, Fort Collins CO Structural Recommendations Gentlemen: At your request, I inspected the subject property and have evaluated the materials necessary to construct a loft area above the current living room, similar to the original house plan "optional" loft". This loft area is proposed to, be approximately 14'x14' in size. Based on my calculations the loft structure can be constructed of engineered floor joists equal to Trust Joist TH's 9.5" deep with 1.75"x9.5 LVL ledger boards. The ledgers shall be attached to the existing framing with a minimum of (3) "Ledger Lok" screws to each existing stud. The exterior wall ledger shall be attached to the existing window header or cripple framing in a similar screw pattern. The new loft joists shall be hung from the ledger with "Simpson" joist hangers. Please give mega,'d!ilh1f` oq have any questions or if I may be of further assistance. pO GIs,>F Sincerely$����,�\ '�p�� E• 6Qo9F�': 35533 ALL ELECTRICAL WORK SHALL BE IN COMPLIANCE WITH THE Greg BovC�IP.E. �� CURRENT N.E.C. PrincipalFSS10NA1��6+.