Loading...
HomeMy WebLinkAbout1123 W Elizabeth St - Special Inspections/Field Verification - 06/06/2011b1((�oK w El zal eJ/ s i I I FORT COLLINSMIDWEST INC. 3818 PLATTE CT. FORT COLLINS, CO. 80526 PHONE (970) 223-5421 FAX (970) 225-2814 TESTING, ADJUSTING & BALANCING OF H.V.A.C. & HYDRONIC SYSTEMS GENERAL INFORMATION PROJECT LOCATION ARCHITECT MECHANICAL ENGINEER MECHANICAL CONTRACTOR BALANCING TECHNICIAN DATE INSTRUMENTS USED VELGRID FLOW HOOD ANEMOMETER SPEED INDICATOR AMMETER VOLTMETER POWER HARMONICS ANALYZER DIGITAL MICROMANOMETER PRESSURE GAGE PRESSURE GAGE -DIFFERENTIAL ULTRASONIC FLOW METER THERMOMETERS IAQ METER CO2 & CO PARADISE NAILS & SPA FORT COLLINS, COLORADO WILLIAM C. HARRISON JUNE 2011 SHORTRIDGE AIRDATA MULTIMETER FLUKE 36 TRUE RMS FLUKE 36 TRUE RMS SHORTRIDGE AIRDATA MULTIMETER PROJECT ALTITUDE 5000' ' SHORTRIDGE BAROMETRIC CORRECTION IS AUTOMATIC. WILLIAM C. HARRISON IS A MEMBER OF THE ASSOCIATION OF ENERGY ENGINEERS, AND IS A CERTIFIED TESTING, ADJUSTING AND BALANCING PROFESSIONAL. //D 3 W f-/;zab e.fA ST 8//o1689 FORT COLLINS/MIDWEST, INC. EQUIPMENT DATA PROJECT PARADISE NAILS & SPA (A) FAN UNIT # INLINE FAN SUPPLY MAKE BROAN MODEL # L-700 (FROM SCHEDULE) SERIAL # NO NAMEPLATE RATING NOT GIVEN (B) MOTOR *NO ACCESS TYPE HORSEPOWER MEAS. VOLTS (L/L) MEAS. VOLTS (L/G) 122 INITIAL AMPS FINAL AMPS 1.2 (C) STARTER NONE EXIST. THERMALS REQ'D. THERMALS REMARKS BUILT IN OVERLOAD PROTECTION (D) SHEAVES DRIVEN DRIVER DRIVEN CHANGE DRIVER CHANGE INITIAL RPM DIRECT DRIVE DIRECT DRIVE (E) STATIC PRESSURE IN INCHES RATED PF/EFF RATED SPEED RATED VOLTS RATED AMPS PHASE SERVICE FACTOR FRAME SIZE EXIST AMP RATING REQ'D AMP RATING BORE SIZE BORE SIZE BELTS/SIZE BELT CHANGE FINAL RPM FILTER IN OUT DROP HEAT COIL IN OUT DROP COOL COIL IN OUT DROP FAN IN - 0.306 OUT 0.232 RISE 0.538 (F) MEAS. AIR FLOW REQ'D. 700 CFM FINAL 756 CFM DIRECT DRIVE PAGE 1 eYA sal BIM /6g FORT COLLINS/MIDWE T, INC. EQUIPMENT DATA PROJECT PARADISE NAILS & SPA (A) FAN UNIT # INLINE FAN EXHAUST MAKE BROAN MODEL # L-700 (FROM SCHEDULE) SERIAL # NO NAMEPLATE RATING NOT GIVEN (B) MOTOR *NO ACCESS TYPE HORSEPOWER MEAS. VOLTS (L/L) MEAS. VOLTS (L/G) 122 INITIAL AMPS FINAL AMPS 1.2 (C) STARTER NONE EXIST. THERMALS REQ'D. THERMALS REMARKS BUILT IN OVERLOAD PROTECTION (D) SHEAVES DRIVEN DRIVER DRIVEN CHANGE DRIVER CHANGE INITIAL RPM DIRECT DRIVE DIRECT DRIVE (E) STATIC PRESSURE IN INCHES RATED PF/EFF RATED SPEED RATED VOLTS RATED AMPS PHASE SERVICE FACTOR FRAME SIZE EXIST AMP RATING REQ'D AMP RATING BORE SIZE BORE SIZE BELTS/SIZE BELT CHANGE FINAL RPM FILTER IN OUT DROP HEAT COIL IN OUT DROP COOL COIL IN OUT DROP FAN IN - 0.313 OUT 0.105 RISE 0.418 (F) REMARKS DIRECT DRIVE PAGE 2 S-� FORT COLLINS/MI WEIT, INC. AIR BALANCE DATA PROJECT PARADISE NAILS & SPA SYSTEM EXHAUST FINAL OPENING TYPE SIZE CFM EXHAUST-1 CD 2408 193 EXHAUST-2 CD 2408 198 EXHAUST-3 CD 2408 308 TOTAL 699 REMARKS PAGE 3