HomeMy WebLinkAbout6579 Rookery Rd - Disclosures/Final Energy - 08/30/2005THERMAL
CONCEPTS
quMASCO CONTRAT
August 30, 2005
ENVIRONMENTS FOR �j�1 W
LE_
�;,• HEARTH FRoDUCTR
� ..}�.,,.,, P.O. Box 270066RFort Collins, CO 80527
TOR SERVICES G'�n (970) 223-7090 • Fax (970) 223-7098
RE: Brannen Design & Construction
P.O.Box 270578
Ft. Collins CO 80527
Project: 6579 Rookery Rd
The following is a list of the trade-offs used to achieve the 2004 energy code requirement.
The house in Fossil Lake Ranch has a Final HERS score of 81
Area
Value
Notes
House faces
West
-
Exterior walls
R-13
Basement walls
R-11.6
R-19 to 2x6 walls and R-13 fiberglass to furred walls
Some unfinished walls no insulation in storage rooms
Floors.
R-3 8
Windows
2.79
Field varified
Air infiltration
.35 ACH
The most allowed without fresh air ventilation.
Ceiling insulation
R-38
Blown Cellulose
Heating System
78 AFUE
Effective AFUE of combined units are 80%
Cooling System
10 SEER
--
Water Heater
.54 EF
Assuming a standard water heater naturally vented
Crawls ace
No crawls ace
Sincerely,
Paul Higman
Energy Rater
1/0 Summary Report
General Information
RatingID: 21993
Rating Type: Final
Certificate:
Ordered By: Brannen Design & Construction
6579 Rookery Rd, Ft. Collins, CO 80528
Rater: 158 Paul Higman -
Date Rated: 8/30/2005
Total Area: 8694
Electric Utility = 60, Ft.Collins - Energy
Gas Utility = 6, Xcel Energy
Output Summary
Topic
Ref Hse
St Code
AS -IS
UP 1
UP 2
UP 3
UP 4
UP 5
Rating Score
-
70.9
81
0
0
0
0
0
Total Electricity Cost
$981.0
$1123.0
$994.0
—
Total Fuel Cost
$2758.0
$3676.0
$2599.0
PV Cost Benefit
-
-
Total Electricity Use(kWh)
15419
17650
15629
0
0
0
0
0
Total Fuel Use(Therms)
2714
3618
2558
0
0
0
0
0
Heating Electricity(kWh)
457
622
461
0
0
0
0
0
Cooling Electricity(kWh)
1464
3529
1669
0
0
0
0
0
DHW Electricity(kWh)
0
0
0
0
0
0
0
0
Appliance Electricity(kWh)
13498
13498
13498
0
0
0
0
0
Heating Fuel(Therms)
2022
2926
1876
0
0
0
0
0
Hot Water Fuel(Therms)
529
529
519
0
0
0
0
0
Appliance Fuel(Therms)
161
161
161
0
0
0
0
0
Electricity Savings(kWh)
-
-
2161
Fuel Savings(Therms)
-
-
1060
-
Electricity Cost Savings
-
-
$129.0
Fuel Cost Savings
-
-
$1077.0
-
Total Cost Savings
-
-
$1206.0
Design Heating Load(kBtu/h)
-
158.9
108.65
0
0
0
0
0
Design Cooling Load(kBtu/h)
-
67.74
37.39
0
0
0
0
0
Price Of Electricity($/kWh)
064
.064
.064
.000
.000
.000
.000
.000
Price Of Fuel($/Therm)
1.016
1.016
1.016
.000
.000
.000
.000
.000
Electric Utility Service
-
-
$46.92
Gas Utility Service
-
-
$108.00
Total Upgrade Costs
-
-
$2820.00
Package Present Value
-
-$15273.33
CO2 Reduction(tons)
-
-
8.23
.00
.00
-nn
nn
nn-
8/30/2005 Page 1 of 4