HomeMy WebLinkAbout1009 Andrews Peak Dr - Disclosures/Final Energy - 08/15/2005Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 08/15/05 (970)377-1056 CUSTOMER: BLS Development 1009 Andrews Peak Dr. 103 Fort Collins Co BUILDING CONDITIONS: Interior Temp = 70 F Exterior Temp = 55 F Volume = 21090 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 3 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 55 75 1508 1.7 Ring A 50 59 1339 —0.8 Ring A 48 54 1282 —1.1 Ring A 44 45 1171 —1.6 Ring A 37 33 1005 0.2 Ring A 31 24 858 1.9 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9968 C = 28.44 n = 0.987 Results: Air Flow @ 50 Pascals : 1350 CFM50 +/— 0.7% 3.84 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 31.66 Square Inches +/— 9.8% Equivalent Leakage Area (CANADA) = 81.01 Square Inches +/— 6.1% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) 99 CFM = 33.2 CFM/OCCUPANT = 0.28 AIR CHANGES PER HOUR