Loading...
HomeMy WebLinkAbout6109 Estuary Ct - Special Inspections/Engineering - 03/12/2009Grown Zniitwrin9, M. 5trt+ctural2;ngsneers" * inspectsons March 12 2009 Sovick Design/Builders, Inc 750 Havel Ave Fort Collins, CO 80521 Re Wall Steel Observation for 6019 Estuary Ct , Fort Collins CO Crown Engineering, llc Project No 78-01-04-04 Gentlemen We have visually observed the concrete foundation wall steel reinforcing placed in the forms at the residence under construction at the above referenced location This observation was performed on March I I , 2009 It is our opinion that the reinforcement was in general conformance with the foundation plan, drawn by Crown Engineenng, llc , Job No 78-01-04-01, dated January 20, 2009 If you have any questions, please do not hesitate to contact me at (970) 691-4239 Sincerely, Grown ZfM1h'NgtiflPCf'1LUi-' , Uc. Main Office 524 Stover Street Fort Collins Colorado 80524 Phone (970) 498-9537 Cell (970) 691-4239 e mail reyess(3 r@msn com Grown Zniineerini, M. Struc'tUrA,t Z 9sneen" I lnsreawns May 7, 2009 Sovick Design/Builders, Inc 750 Havel Ave Fort Collins, CO 80521 Re Foundation wall Damproofing Observation for 6109 Estuary Ct , Fort Collins, CO Crown Engineering, llc Project No 78-01-04-07 Gentlemen We have visually observed the foundation wall damproofing installed around the extenor penmeter of the basement of the home under construction at the above referenced location The damproofing consists of the DMX Flexsheet system coupled with the ICF forms used dunng foundation concrete work The system consists of a High Density Polyethylene barrier that drains moisture down to the extenor perimeter drains of the home It is our opinion that the damproofing has been installed to meet the general requirements as recommended by the manufacturer and per generally accepted construction practices If you have any questions, please do not hesitate to contact me at (970) 691-4239 O------ 1-- plc - Main Office 524 Stover Street Fort Collins Colorado 80524 Phone (970) 498-9537 Cell (970) 691-4239 e mail reyessS@msn com Grown Zn jine -rwj, M. Structmrat Z"tneert" � rwrctww May 7, 2009 Sovick Design/Builders, Inc 750 Havel Ave Fort Collins, CO 80521 Re Exterior Perimeter Drain Observation for 6109 Estuary Ct , Fort Collins, CO Crown Engmeermg, Ile Project No 78-01-04-06 Gentlemen We have visually observed the perimeter drain being mstalled around the exterior perimeter of the basement of the home under construction at the above referenced location The dram consists of 4" perforated pipe covered with a permeable sock It is placed around the basement perimeter and covered with approxmiately 10" plus or minus of 3/4" or less pea gravel It is our opinion that the perimeter dram as installed is an adequate means of drammg any ram or irrigation water that may filtrate down to the basement elevation of the home If you have any questions, please do not hesitate to contact me at (970) 691-4239 Smcerely� D REG3 Reyes Structural Main Office 524 Stover Street Fort Colhns Colorado 80524 Phone (970)498-9537 Cell (970) 691-4239 e mail reyessi5Qmsn com Grown Z"ineeri", llc. Structural Z"sneert" * Inspectsons May 7, 2009 Sovick Design/Builders, Inc 750 Havel Ave Fort Collins, CO 80521 Re Garage Footing Observation, 6109 Estuary Ct , Fort Collins, CO Crown Engineering Ilc Project No 78-01-04-05 Gentlemen We have visually observed the footing sizes for the garage at the residence under construction at the above referenced location This observation was performed on April 7, 2009 It is our opinion that the footing sizes and widths were in general conformance with the foundation plan drawn by Crown Engineering, I Ic , Job No 78-01-04-01 dated January 20, 2009 and revised on March 2, 2009 If you have any questions, please do not hesitate to contact me at (970) 691-4239 Main Office 524 Stover Street Fort Collins Colorado 80524 Phone (970) 498 9537 Cell (970) 6914239 e marl reycssi5@msn com crown Z"ineeri", llc. StrWtt+rXt Z"tneert" I fnspecttons May 7, 2009 Sovick Design/Builders, Inc 750 Havel Ave Fort Collins, CO 80521 Re Garage Wall Steel Observation for 6109 Estuary Ct , Fort Collins, CO Crown Engineering, Ilc Project No 78-01-04-05b Gentlemen We have visually observed the concrete foundation wall steel reinforcing placed in the forms for the garage at the residence under construction at the above referenced location This observation was performed on April 8, 2009 It is our opimon that the reinforcement was in general conformance with the foundation plan, drawn by Crown Engineering, llc , Job No 78-01-04-01, dated January 20, 2009 and revised on March 2, 2009 If you have any questions, please do not hesitate to contact me at (970) 691-4239 Sincerely, Grown. Reyesa �ibifto, P E Structural E�,, Lope Sao- 0 "� ONAL E Mam Office 524 Stover Street Fort Collin Colorado 80524 Phone (970)498-9537 Cell (970) 691-4239 e mail rcyessl3 msn com