Mr. Skip Wenkle
Centex Itomcs arch 1. 20o5
10333 E. my Creel: Rd, Slsite 300
Englewood, Co $fll 11
Re: Lind Property Subdivision
2132 Clipper Way
T,ot 214, Block 10, Plan G-2 A.
Pro ect No. FOO-04001-0073
Dear Mr. Henkie;
.'n accordance witll yoar request, this office visited the above rcferenccsd address on ;February 23. 2005
The purpose o.f OLT visit %sas to obseYl-e and evaluate condition of the: reported off.Sc t sill Plate:, in the
garage of rho residenc.e.
OBSER VATT.OIV;
The garage of the residence is at rear and faces north, .Based on our observation. ironing on both sides of the garage return walls at the garage door is offset relative to the Erertical face of the fottndat c,n wain.
During our visit we noted the folio -wing:
1 West garage return , •all is broken 4"-5" from east end of the fo-tndation wall. The fracture
extends 4" below top of The wall and exposed anchor bolt due to the fracture was notes{.
2. Sill p?ate along east garage wall extends beyond the end cf the return -vall 2"
3- Top exterior particm of the foundation wall at oast return wall "s chipped, The fractured section i 4"x. 4" wtd exPOSe�'-' anchalr bolt was noted.
-1. :tiorthcast corner of the garage foundation wall is broken. The broken sect.ion is $" high ? k along the north wall, and 5" long along the east %vat1. mf
BVALUATI0N. .PPco.x-N11lITIQ S,
Rased on th.c observed condition, with regards to the above noted off set $i11 condition~, it �s i>e,r
adequacy
nil of t1 based on r�urnber of `t�.mmers provided, the offset condition of the sill plates doei not of Oct
aiiccluac} of i11c sillifoundation. Rowever, we recommend the fractured section o.f the foundation walls.
notee in above noted items I and 3 be repaired per the attached detail SK-1. Additionally, we recomme„d
the fracture section of the; foundation walls at northeast corner. see item 4 above. be cleanse to rrmOvc all
lose rnareria.l prior to application of bonding agent and patching the section witl- "five. Star Structurai
C_'oncretr V/0. Refer to the attached detail SK-i for information on material and required inspcction4_
If yo,.! have any �Tuestions, please contact this Office.
RL5pectiully,
The Weintraub Organization, Ltd.
Roger B. I4agaveg, P.E.
Repair Department Proic,:t En4inecr