Loading...
HomeMy WebLinkAbout6987 Rosemont Ct - Disclosures/Final Energy - 02/01/2005Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 02/01/05 (970)377-1056 CUSTOMER: Kaufman and Broad 6987 Rosemont Ct Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 40 F Volume = 26050 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 57 96 1682 0.1 Ring A 53 90 1630 —0.9 Ring A 43 81 1547 0.2 Ring A 35 74 1479 1.8 Ring A 30 64 1377 —0.7 Ring A 22 53 1254 —0.7 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9952 C = 499.97 n = 0.300 Results: Air Flow @ 50 Pascals : = 1616 CFM50 +/— 0.6% 3.72 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 214.79 Square Inches +/— 3.4% Equivalent Leakage Area (CANADA) = 292.86 Square Inches +/— 2.1% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 119 CFM = 59.5 CFM/OCCUPANT = 0.27 AIR CHANGES PER HOUR