Loading...
HomeMy WebLinkAbout709 Keenesburg Ct - Special Inspections/Engineering - 07/19/2004Irerracan 301 N. Howes • P.O. Box 503 Fort Collins, Colorado 80521-0503 (970) 484-0359 Fax: (970) 484-0454 July 19, 2004 DR Horton, Melody Series 11031 Sheridan Blvd. Westminster, Colorado 80020 Attn: Mr. Corey Weaver Re: Exterior Perimeter Drain Observation, Ridgewood Hills 3`d Filing 709 Keenesburg Court - Lot 303 Fort Collins, Colorado Terracon Project No. 20005162 A representative of Terracon observed the perimeter drain at the above referenced address on July 14, 2004, as requested. A four -inch diameter perforated PVC pipe had been placed around the exterior perimeter of the basement and crawl -space foundations with an impervious PVC membrane beneath the drainage system. The drainage pipe appeared to exhibit positive drainage toward the sump pit located within the basement area. We also observed 1 to 1-1/2-inch washed gravel placed above and below the pipe and drainage filter fabric above the gravel. The waterproof dampening was also observed and in our opinion was uniformly applied to the exterior foundations. In our opinion the exterior perimeter drain was constructed in general accordance with the plans and specifications for this project. Sincerely, TERRACON Reviewed By' Vq�pA R,clr� � �712 Benjamin Ruder, E.I. David A. Ric ,► {?1fti,...,,.r Staff Engineer GeotechnicaI ngirteer/Department Manager Copies to: (2) Addressee (1) Brian Kelly — DR Horton, Melody Series Arizona ■ Arkansas ■ Colorado ■ Idaho ■ Illinois ■ Iowa ■ Kansas ■ Minnesota ■ Missouri ■ Montana Nebraska ■ Nevada ■ New Mexico ■ North Dakota ■ Oklahoma ■ Tennessee ■ Texas ■ Utah ■ Wisconsin ■ Wyoming Quality Engineering Since 1965