Loading...
HomeMy WebLinkAbout6714 Rose Creek Way - Disclosures - 08/17/2004 (2)Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 08/17/04 (970)377-1056 CUSTOMER: Kaufman and Broad 6714 Rose Creek Way #2 Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 70 F Volume = 15278 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 57 53 1291 -0.0 Ring A 50 45 1191 -0.1 Ring A 42 36 1066 -0.4 Ring A 33 27 925 0.2 Ring A 24 19 777 2.3 Ring A 18 12 619 -2.7 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9988 C = 107.66 n = 0.615 Results: Air Flow @ 50 Pascals : 1191 CFM50 +/- 0.6% = 4.68 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 71.54 Square Inches +/- 3.6% Equivalent Leakage Area (CANADA) = 130.14 Square Inches +/- 2.2% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) 88 CFM = 43.9 CFM/OCCUPANT = 0.34 AIR CHANGES PER HOUR