On May 8 2008 this office observed and approved the continuous spread footing form
dimensions (widths and depths) and the interior square footing form dimensions (widths and
depths) at the location referenced above The size type and installation of the continuous spread
footing and the interior square footing reinforcement is appioved At the time of this
observation the #4 hooked dowel reinforcement was on site and it is to be installed in the freshly
placed footing concrete The dowel installation and spacing is to be verified when the
foundation wall reinforcement is observed
The continuous footing foim dimensions and reinforcement and the inteiioi footing form
dimensions and reinforcement are consistent with the foundation design by Axiom Structutal
Engineeiing, LLC, project number JAMB 07J19 03-25, dated November 19 2007
If you have any questions, of if we may be of furthei service please contact this office at your
convenience
Sincerely
Axiom Structural Engineering, LLC
RUsserltT—Zeetewev E I T _
Steve H Kellums, P E
Principal
REG/%kF• ��.
31696
MAY 0 8 2008
OFFICE (970) 461 1555 FAX (970) 461 1582 EMAIL Axiom2000@mcleodusa net
qW AXIOM
STRUCTURAL ENGINEERING LLC
1395 SOUTH GARRELD AVENUE
LOVELAND COLORADO 80537
May 12 2008
Project Number
JAMB-07J 19-03-45
Jamestown Builders, LLC
P O Box 2125
Fort Collins, Colorado 80522
Re Foundation Wall Reinforcement Observation
Lot 44, Bellwether Subdivision
2274 Bellwether Lane
Fort Collins, Colorado
Dear Mr Everitt
On May 12 2008 this office observed and approved the horizontal and vertical reinforcement
placed In the foundation wall forms at the location iefeienced above The reinforcement
observed meets the specifications for size, type and installation in accordance with the
foundation design drawings by Axiom Stluctural Engineering, LLC project number JAMB
07J19-03-25 dated November 19 2007
We also observed the #4 rebar Ufei ground rod that projects vertically from the top of the East
basement foundation wall The Ufer ground rod is lapped approximately 3 -6 and it is tied to
the bottom row of the continuous horizontal foundation wall reinforcement The vertical
projection of the Ufer' is located approximately 5 -9 from the exterior Southeast corner of the
basement foundation along the East basement foundation wall
Please refer to the, enclosed photogiaph�, If you have any questions of if we may be of further
service, please contact this office at your convenience
Sincere
Structural Engineering, LLC
: Keve H Kellums, P E
Principal
Encloseuies
0 RfGjs.
MAY 1 2 2008
OFFICE (970) 461 1555 FAX (970) 461 1582 EMAIL Axiom2000@mc1eodusa net
z t
" t-
r \
�`�.,,4�:_
t------------
• 7 AJL
-
-77
16
4
x
h
_
!`yS
_
,
g
j
008 :46
1.w.1
AXI®lO/I
STRUCTURAL ENGINEERING LLC
1395 SOUTH GARFiELD AVENUE
May 15 2008 LOVELAND COLORADO 80537
Project Number
JAMB 07J 19 03 55
Jamestown Buildeis LLC
P O Box 2125
Fort Collins Colorado 80522
Re Foundation Sub -Dram and Damp Proofing Observation
Lot 44, Bellwether Subdivision
2274 Bellwether Lane
Fort Collins, Colorado (Larimer Countv)
Dear Mr Everitt
On May 15 2008 this office observed the foundation sub drain materials installed around the exterior
perimeter of the basement foundation The sub drain pipe is connected to a Sump pit in the basement
The homeowner should check the sump pit periodically for -vtater If water accumulates in the pit a
licensed plumber and electrician should install a submersible pump with an automatic float switch Tilt
pipe from the pit should discharge at an acceptable location away from all foundation walls window
wells and exterior concrete flatwork At the time of this observation the foundation sub drain materials
appeared to be properly installed
We also observed the spray on damp pioofing applied to the exterior of the basement foundation walls
The damp proofing appears to adequately cover the basement foundation walls Please note that spray on
damp proofing is typically effective for reducing moisture infiltration in the absence of hydrostatic
pressure Spray on damp proofing does not cieate a waterproof b irrier that is capable Of resisting
moisture infiltration under hydrostatic pressure Thus it may be possible for water to infiltrate the
foundation particularly at form tic penetrations and hairline cracks that sometimes occur from shrinkage
especially near basement window openings It is important to piovide and maintain drainage paths that
allow all surface water to flow quickly away from all foundation walls window wells and exterior
concrete flatwork
Please refer to the enclosed photographs if you have any questions of if we may be Of fiirther seivice
please contact this office at your convenience