HomeMy WebLinkAbout2120 Andrews St - Disclosures - 08/12/2003Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 08/12/03 (970)377-1056 CUSTOMER: US Homes 2120 Andrews Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Volume = 24500 Cu. Ft. Number of Stories = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: Exterior Temp = 85 F Above Grade Surface Area = 0 Sq. Ft. Number of Occupants = 2 House Pressure Fan Pressure CFM %Error Fan Configuration 57 109 1871 —0.8 Ring A 48 87 1673 0.3 Ring A 41 73 1534 2.9 Ring A 35 52 1297 —2.6 Ring A 30 43 1181 —0.9 Ring A 26 36 1081 0.5 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9960 C = 104.53 n = 0.715 Results: Air Flow @ 50 Pascals : 1717 CFM50 +/— 1.0% 4.21 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 79.90 Square Inches +/— 7.6% Equivalent Leakage Area (CANADA) = 159.44 Square Inches +/— 4.7% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 127 CFM = 63.3 CFM/OCCUPANT = 0.31 AIR CHANGES PER HOUR