Loading...
HomeMy WebLinkAbout827 Apex Dr - Disclosures - 08/10/2003Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 08/10/03 (970)377-1056 CUSTOMER: John Walz `Dy- 827 Apex"C" Fort Collins Co 3UILDING CONDITIONS: Interior Temp = 70 F Exterior Temp = 75 F Volume = 15000 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 4 Wind Shield Factor = 1 SOUSE TEST : Depressurized Fan Model = 3 Performed By SARA 3ata Points: House Pressure Fan Pressure CFM %Error Fan Configuration 54 43 1167 —1.9 Ring A 45 38 1098 1.6 Ring A 35 29 961 1.4 Ring A 28 22 838 —0.5 Ring A 20 16 716 1.4 Ring A 14 10 567 —3.2 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9968 C = 146.44 n = 0.525 Results: Air Flow @ 50 Pascals : 1142 CFM50 +/— 1.1% 4.57 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 85.97 Square Inches +/— Equivalent Leakage Area (CANADA) = 144.09 Square Inches +/— Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) 84 CFM = 21.0 CFM/OCCUPANT = 0.34 AIR CHANGES PER HOUR 4.7% 2.8%