Loading...
HomeMy WebLinkAbout2144 Baldwin St - Special Inspections/Engineering - 03/02/2004SCOTT, COX & ASSOCIATES, INC. consulting engineers 4AK March 2, 2004 The Genesee Company 4821 Wheaton Drive Ste. 200 Fort Collins, Colorado 80525 Project No: 1782-69-19-05 Gentlemen: On February 25, 2004, a representative of Scott, Cox & Associates, Inc. visually observed the perimeter drain system and damp -proofing for the new residence under construction at Lot 19, Block 7, West Chase, (2144 Baldwin Street), a subdivision of Fort Collins, Colorado. We observed that the completed drain system consisted of perforated rigid PVC pipe surrounded by gravel, overlying a plastic liner, set outside of the foundation walls. The drain appeared to be located below the footing level and is to discharge to an interior sump pit. We observed that the damp -proofing consisted of asphaltic spray -on coating. It appeared that the damp -proofing coating adequately covered the foundation wall. As a result of our observations, it is our opinion that the drainage system and damp -proofing were in general conformance with the plans and specifications. If you have any questions about our observations or this report, feel free to contact our office. Sincerely, SCOTT, COX & ASSOCIATES, INC. Reviewed by: Steve Stefko Engineering Technician GA0ffice\Letters\Genesee Company, The\1782-69-19-5.wpd 5110 Granite Street, Suite D • Loveland , Colorado 80538 (970) 663-0138 • Fax: (970) 663-1660 Serving Colorado with offices in • Boulder Longmont • Loveland