Loading...
HomeMy WebLinkAbout1514 Tang Ct - Disclosures - 07/11/2003Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 07/11/03 (970)377-1056 CUSTOMER: US Homes 1514 Tang Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 70 F Volume = 31500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 57 144 2117 1.1 Ring A 52 127 1989 —0.9 Ring A 45 113 1878 —0.1 Ring A 38 96 1732 —0.4 Ring A 30 77 1553 —0.5 Ring A 21 57 1338 0.9 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9986 C = 328.70 n = 0.458 Results: Air Flow @ 50 Pascals : 1972 CFM50 +/— 0.4% 3.76 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 175.84 Square Inches +/— Equivalent Leakage Area (CANADA) = 277.16 Square Inches +/— Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 145 CFM = 72.7 CFM/OCCUPANT = 0.28 AIR CHANGES PER HOUR 2.9% 1.8%