HomeMy WebLinkAbout1122 Mountain Ave - Special Inspections/Engineering - 12/13/2002Charles C Robinson, PE (970) 493-0178
319 South Grant Avenue, Fort Collins, Colorado 80521 Fax(970) 407-7392
Friday, December 13, 2002
Fort Collins Building Department
and
Steve Josephs
Craftsmen Builders
319 East Magnolia Street
Fort Collins, Colorado 80521
Dear Sirs,
RE: Foundation Footing and Wall Reber Inspection, 1122 West Mountain Avenue, Fort Collins, Colorado.
Our office was asked by Steve Josephs of Craftsmen Builders to inspect both the footing and foundation of the two-
story WOO' guest house addition being built at 1122 West Mountain Avenue. Our office provided engineering
support and the stamped plans submitted to the building department.
On December 6, 2002 I inspected the footings for the perimeter walls. The continuous rebar was in place with the
verticals ready to install during concrete placement. Concrete was scheduled for Ipm but had been moved back to
later in the afternoon. It is our opinion that the footers meet the intent of our design.
On December 9, 2002 I inspected the wall forms. The horizontal and vertical rebar was in place and the forms
appeared to be located appropriately. Due to supply problems, the contractor did not have 5/8" anchor bolts on
site. Because of this, we allowed the use of/s" anchor bolts 3' c/c instead of the 5/8" anchor bolts 5' c/c. The
concrete was scheduled for later in the afternoon. It is our opinion that this foundation meets the intent of our
design.
Please call if there are any questions.
This inspection and letter are limited to the specifrc items listed and in no way implies a cerVkation of the stricture, its systems or site work. No
liability is assumed for future loss of value, marketability or any other loss claims.
File: Craftsmen 1122 W Mountain 12-12-2002 FFI Job Reference: 02-283