Loading...
HomeMy WebLinkAbout6969 Rosemont Ct - Disclosures - 04/21/2004Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 04/21/04 (970)377-1056 CUSTOMER: Kaufman and Broad 6969 Rosemont 0. Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 35 F Volume = 21500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 57 95 1665 -1.7 Ring A 51 85 1576 0.2 Ring A 46 77 1501 2.2 Ring A 41 66 1391 2.2 Ring A 36 50 1212 -3.0 Ring A 30 41 1099 --0.7 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9905 C = 115.98 n = 0.663 Results: Air Flow @ 50 Pascals : 1552 CFM50 +/- 1.0% = 4.33 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 82.44 Square Inches 11.2% Equivalent Leakage Area (CANADA) = 156.79 Square Inches +/- 7.0% Estimated Nbtural Infiltration (50 Pascal Flow Divided By 13.6) 114 CFM 57.2 CFM/OCCUPANT = 0.32 AIR CHANGES PER HOUR ft1w vh