HomeMy WebLinkAbout1597 City Park Ave - Violations - 05/14/2003May-23-03 11:22A Boiler/Public Sa-Pety o v% S 303-318-8488 P,O2 Bill Owens Governor Jeffrey M. Wells Executive Director Richard O. Piper Division Director May 14, 2003 CITY OF FORT COLLINS PO Box 590 FT COLLINS, CO W522-0580 DEPARTMENT OF LABOR AND EMPLOYMENT Division of Oil and Public Safety �E� l -4 Boiler Inspection A� � SOZ09S' 7'7 Tower a A+a a > SS iJ 7 / C_ 1� 1515 'pah SL oe St Denver. CD 80202-2117 N&u_ Att�. 303 3141-34184 Fax: 303 3184MM Inspector: CONNER, DAVE Agency: STATE OF COLORADO Jurisdiction: 63435 Location: CITY PARK, MAIN POOL BOILER ROOM Address: 1599 CITY PARK AVENUE, FORT COLLINS NOTICE OF REQUIREMENTS An inspection conducted on 05/08/2003 indicates that specific repairs must be made to the referenced boiler/pressure vessel in order to bring it into compliance with minimum safety standards. See the following LIST Of: VIOLATION(S). Please complete all repairs within 45 days from the date of this letter. When repairs are done, sign and date the bottom of this Notice and mail or fax it to the Boiler Inspection Office. If you cannot complete repairs within 45 days, call the Program Manager at 303-318-8481 or 303-318-8506 to request an extension. Operating a non -compliant boiler or pressure vessel is prohibited by Colorado law. [See 9-4-108(2) CRS] If repairs to this vessel are: not completed timely, the vessel may be flagged for shutdown and a reinspection fee may be charged. LIST OF VIOLATION(S) IDENTIFIED: (*)The safety limit temperature control is not equipped With a manual reset (lockout). Install safety limit temperature control with lockout requiring manual reset as per ASME CSD-1,CW-410(C). I certify that all violations noted on the above LIST OF VIOLATIONS have been corrected Dated this'Z Jday of M o��/ Zoo 3. Party Responsible for compliance Jurisdiction Number: 63435 Ron Kechter, P.E. Facilities Project Manager City of Fort Collins Operations Services Department Project Management, Planning & Design 117 North Mason Street P.O. Box 580 Fort Collins, CO 80522-0580 Office: (970) 221-6805 Fax: (970) 221-6534 e-mail: rkechter@fcgov.com 303-318-8488 P.03 May- 23 - 03 11 : 22A Boiler/Public SEtfety r Bill Owens Governor Jeffrey M. Wells Executive Director Richard O. Piper Division Director May 14, 2003 CnY OF FORT COLLINS PO Box 580 FT COLLINS, CO 80522-0580 DEPARTMENT OF LABOR AND EMPLOYMENT Divisb3n of On and Public Safety Boiler Inspection T(ow 3, :suite 610 1S15 Arapahoe St. Denver, CO 80202.2117 3013 3113-SUK Fax: 303 318-8488 Inspector: CONNER, DAVE Agency: STATE OF COLORADO Jurisdiction: 09346 Location: CITY PARK, MAIN POOL Address: 1599 CITY PARK AVENUE, FORT COLLINS NOTICE OF REQUIREMENTS An inspection conducted on 05/08/2003 indicates that specific repairs must be made to the referenced boiler/pressure vessel in order to bring it into compliance with minimum safety standards. See the following LIST OF VIOtATION(S). Please complete all repairs within 45 days from the date of this letter. When repairs are done, sign and date the bottom of this Notice and mail or fax it to the Boiler Inspection Office. If you cannot complete repairs within 45 days, call the Program Manager at 303-318-8481 or 303-318-8506 to request an extension. Operating a non -compliant boiler or pressure vessel is prohibited by. Colorado law. [See 9-4-108(2) CRS] If repairs to this vessel are not completed timely, the vessel may be flagged for shutdown and a reinspection fee may be charged. LIST OF VIOLATION(S) IDENTIFIED: (*)The safety limit temperature control is na: equipped with a manual reset (lockout). Install safety limit temperature control with lackcut requiring manual reset as per ASME CSD-I,CW-410(C). (*)The boiler is not equipped with a manual reset (lockout) on the low water fuel cutoff deivce. Install a LWCO device with manual reset as per ASME CSD-1, CW-120(B,1), CW-130(D), CW-140(B), CR-210. 1 certify that all violations noted on the above LIST OF VIOLATIONS have been corrected.�� Dated this ZS Jday of JA 20 3 Party Responsible for compliance Ron xechter, P.E. Jurisdiction Number: 09346 Facilities Project Manager City o(FoR Collins Operations Services Department Project Management, Planning & Design 117 North Mason Street P.O. Box 580 Fort Collins, CO 80522-0580 Office: (970) 221-6805 Fax: (970) 221-6534 e-mail: rkechter@fcgov.com