Loading...
HomeMy WebLinkAbout2608 Brush Creek Dr - Special Inspections/Engineering - 02/03/2003February 3, 2003 James Company 5433 Old Mill Road Fort Collins, Colorado 80528 Attn: Mr. Pete Osborne Construction Superintendent @ Sage Creek Re: Exterior Perimeter Drain Observation Sage Creek Filing No. 1 Phase 4 2608 Brush Creek Lot 13 Block 4 Fort Collins, Colorado Terracon Project No. 20025133 Gentlemen: Irerracon 301 North Howes • P.O. Box 503 Fort Collins, Colorado 80521-0503 (970) 484-0359 Fax: (970) 484-0454 A representative of Terracon observed the perimeter drain at the referenced site on January 30, 2003, as requested. A four -inch diameter perforated PVC pipe underlain by a PVC impervious liner material had been placed around the exterior perimeter of the basement foundation. The drainage pipe appeared to exhibit positive drainage toward the sump pit located within the basement area. We also observed 1-inch washed gravel placed above and below the pipe and drainage filter fabric placed above the gravel. The waterproof dampening was also observed and in our opinion was uniformly applied to the exterior foundations. In our opinion the exterior perimeter drain was constructed in general accordance with the plans and specifications for this project. Senior Field Technician Copies to: (3) Addressee 0`�pp 0 RE A. RAC,••. ���` Q� yam' 4 David A. i e'P.«..••' ��`` Geotechnical rtment Manager Arizona ■ Arkansas ■ California ■ Colorado ■ Georgia ■ Idaho ■ Illinois ■ Iowa ■ Kansas a Kentucky ■ Minnesota ■ Missouri Montana ■ Nebraska ■ Nevada ■ New Mexico ■ North Carolina ■ Oklahoma ■ Tennessee ■ Texas ■ Utah ■ Wisconsin ■ Wyoming Consulting Engineers & Scientists Since 1965 www.terracon.com