HomeMy WebLinkAbout2608 Brush Creek Dr - Special Inspections/Engineering - 02/03/2003February 3, 2003
James Company
5433 Old Mill Road
Fort Collins, Colorado 80528
Attn: Mr. Pete Osborne
Construction Superintendent @ Sage Creek
Re: Exterior Perimeter Drain Observation
Sage Creek Filing No. 1 Phase 4
2608 Brush Creek Lot 13 Block 4
Fort Collins, Colorado
Terracon Project No. 20025133
Gentlemen:
Irerracon
301 North Howes • P.O. Box 503
Fort Collins, Colorado 80521-0503
(970) 484-0359 Fax: (970) 484-0454
A representative of Terracon observed the perimeter drain at the referenced site on January 30,
2003, as requested. A four -inch diameter perforated PVC pipe underlain by a PVC impervious liner
material had been placed around the exterior perimeter of the basement foundation. The drainage
pipe appeared to exhibit positive drainage toward the sump pit located within the basement area.
We also observed 1-inch washed gravel placed above and below the pipe and drainage filter fabric
placed above the gravel. The waterproof dampening was also observed and in our opinion was
uniformly applied to the exterior foundations.
In our opinion the exterior perimeter drain was constructed in general accordance with the plans and
specifications for this project.
Senior Field Technician
Copies to: (3) Addressee
0`�pp 0 RE
A. RAC,••. ���`
Q� yam' 4
David A. i e'P.«..••' ��``
Geotechnical rtment Manager
Arizona ■ Arkansas ■ California ■ Colorado ■ Georgia ■ Idaho ■ Illinois ■ Iowa ■ Kansas a Kentucky ■ Minnesota ■ Missouri
Montana ■ Nebraska ■ Nevada ■ New Mexico ■ North Carolina ■ Oklahoma ■ Tennessee ■ Texas ■ Utah ■ Wisconsin ■ Wyoming
Consulting Engineers & Scientists Since 1965
www.terracon.com