HomeMy WebLinkAbout6915 Ranger Dr - Disclosures - 03/12/2004 (2)Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 03/12/04 (970)377-1056 ]USTOMER: US HOMES 6 915 Ranger ER-1- Fort Collins ,CO 3UILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 50 F Volume = 38500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 iOUSE TEST : Depressurized Fan Model = 3 Performed By SARA data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 56 177 2300 2.6 Ring A 52 159 21EIl —0.7 Ring A 43 138 2033 —2.6 Ring A 35 127 1952 -1.1 Ring A 28 113 1842 —0.8 Ring A 20 100 1734 2.2 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9797 C = 754.18 n = 0.270 Results: Air Flow @ 50 Pascals s 2173 CFM50 +/— 1.2$ = 3.39 ACH50 (Air Changes --Per-- Hou-r- ) Effective Leakage Area (LBL) = 311.07 Square Inches +/— 6.4% Equivalent Leakage Area (CANADA) = 412.87 Square Inches +/— 3.9% Estimated Natural Infiltration (50 Pascal Flora Divided By 13.6) = 160 CFM 80.0 CFM/OCCUPANT = 0.25 AIR CHANGES PER HOUR