Loading...
HomeMy WebLinkAbout1320 Catalpa Dr - Special Inspections/Engineering - 01/12/2004Irerracon 301 N. Howes • P.O. Box 503 Fort Collins, Colorado 80521-0503 January 12, 2004 (970) 484-0359 Fax (970) 484-0454 Mr. Michael Macfarlane 315 South Coast Highway 101, Ste. U-167 Encinitas, California 92024 Re: Exterior Perimeter Drainage System Observation The Ponds Subdivision 1320 Catalpa Drive - Lot 131 Fort Collins, Colorado Terracon Project No. 20036043 A representative from Terracon observed the exterior perimeter drainage system at the above referenced address on January 12, 2004, as requested. The exterior walls had been backfilled and the drainage pipe was exposed at the northeast and southeast corners of the residence. A 4-inch diameter, perforated PVC pipe was in place at the two locations observed. The drainage pipe was observed to "daylight' at the northeast portion of the lot which was down gradient of the pipe exposed at the northeast corner of the residence. A layer of washed gravel was observed below and above the pipe and drainage filter fabric above the gravel at the two locations observed. The waterproof dampening was also observed and in our opinion was uniformly applied to the exterior foundations. In our opinion the exterior drainage system at the locations observed was constructed in general accordance with the plans and specifications for the project. Reviewed By: David A. Richer, P.E. Geotechnical Engineer/Department Manager Copies to: (2) Addressee Arizona ■ Arkansas ■ Colorado ■ Georgia ■ Idaho ■ Illinois IN Iowa ■ Kansas ■ Kentucky IN Minnesota ■ Missouri ■ Montana Nebraska ■ Nevada ■ New Mexico ■ Oklahoma ■ Tennessee ■ Texas ■ Utah ■ Wisconsin ■ Wyoming Quality Engineering Since 1965