HomeMy WebLinkAbout1815 Brightwater Dr - Special Inspections/Engineering - 11/20/2003Irerracon
301 North Howes • P.O. Box 503
Fort Collins, Colorado 80521-0503
November 20, 2003 (970) 484-0359 Fax: (970) 484-0454
KB Home
8401 East Belleview Avenue
Suite 200
Denver, Colorado 80237
Attn: Mr. Matt Moser
Re: Exterior Perimeter Drainage System Observation
Richards Lake, Phase 1 Development
1815 Brightwater Drive - Lot 137
Fort Collins, Colorado
Terracon Project No. 20005263
A representative from Terracon observed the exterior perimeter drainage system at the above
referenced address within the Richard's Lake Subdivision on November 10, 2003, as requested. At
the time of our site visit, a 4-inch diameter, perforated PVC pipe had been placed around the
exterior perimeter of the basement foundation and an impervious PVC material was placed above
the footings and under the drainage system. The drainage pipe was observed to exhibit positive
gravity flow toward a sump pit located in the lower level/basement portion of the residence. A layer
of washed gravel was also observed below and above the pipe and drainage filter fabric above the
gravel. The waterproof dampening also observed and in our opinion was uniformly applied to the
exterior foundations.
In our opinion the exterior drainage system was constructed in general accordance with the plans
and specifications for the project.
Sincerely,
TERRACON
Glenn
Senior Field Technician
Copies to: (2) Addressee
0PR RG
277 ;
David A. Richer, Fs•.,,„,!.`c9
Geotechnical Engin nt Manager
Arizona ■ Arkansas ■ California ■ Colorado ■ Georgia ■ Idaho ■ Illinois ■ Iowa ■ Kansas ■ Kentucky ■ Minnesota ■ Missouri
Montana ■ Nebraska ■ Nevada ■ New Mexico ■ North Carolina ■ Oklahoma ■ Tennessee ■ Texas ■ Utah ■ Wisconsin ■ Wyoming
Consulting Engineers & Scientists Since 1965
www.terracon.com