Loading...
HomeMy WebLinkAbout7109 Ranger Dr - Disclosures - 03/25/2003Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 03/25/03 (970)377-1056 CUSTOMER: US Homes 7109 Ranger bpi Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 50 F Volume = 39500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 57 156 2161 —1.4 Ring A 50 143 2070 0.1 Ring A 44 130 1974 1.0 Ring A 37 114 1850 2.1 Ring A 30 90 1646 —0.4 Ring A 23 69 1443 —1.9 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9946 C = 370.29 n = 0.440 Results: Air Flow @ 50 Pascals : = 2068 CFM50 +/— 0.8% 3.14 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) 193.12 Square Inches +/-•- 5.4% Equivalent Leakage Area (CANADA) = 299.30 Square Inches +/— 3.3% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) 152 CFM 76.2 CFM/OCCUPANT = 0.23 AIR CHANGES PER HOUR fy�