HomeMy WebLinkAbout1509 Coral Sea Ct - Disclosures - 03/10/2003Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 03/10/03 (970)377-1056 CUSTOMER: US Homes 1509 Coral Sea Ct. Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 50 F Volume = 35500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 57 160 2188 -0.3 Ring A 50 140 2048 1.0 Ring A 42 110 1818 -0.6 Ring A 27 63 1380 -1.8 Ring A 23 55 1290 1.1 Ring A 14 30 956 0.7 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9993 C = 196.32 n = 0.597 Results: Air Flow @ 50 Pascals : 2028 CFM50 +/- 0.5% 3.43 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 127.33 Square Inches +/-- 2.6% Equivalent Leakage Area (CANADA) 227.93 Square Inches +/-- 1.6% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 149 CFM 74.7 CFM/OCCUPANT 0.25 AIR CHANGES PER HOUR