HomeMy WebLinkAbout815 Apex Dr - Disclosures - 01/22/2004Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 01/22/04 (970)377-1056 CUSTOMER: Russ Wells 815 APEX #B �' Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 35 F volume = 15500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 58 55 1271 1.5 Ring A 53 47 1176 —0.6 Ring A 49 42 1112 —1.2 Ring A 42 34 1002 —1.9 Ring A 34 28 910 1.9 Ring A 29 22 808 0.1 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9955 C = 95.32 n = 0.634 Results: Air Flow @ 50 Pascals : 1140 CFM50 +/— 0.7% 4.41 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 65.10 Square Inches +/- 7.4% Equivalent Leakage Area (CANADA) = 120.59 Square Inches +/— 4.7% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 84 CFM 42.0 CFM/OCCUPANT 0.33 AIR CHANGES PER HOUR .dam /Y1 . EL�