Loading...
HomeMy WebLinkAbout1469 Sailcrest Ct - Disclosures - 02/27/2003 (2)I COMMENTS: Retest blower door test of 1469 Sailcrest Ct, Fort Collins, CO 80526 by Evenson Enterprises Inc for purposes of Energy Code Compliance. Original test of 26 February 2003 failed to reach the City's 5.0 ac/hr standard, coming in at 5.79 at 50 Pascals pressure. Builder discovered a cantilever not completely sealed, did work between the garage and interior, caulked around dryer vent, improved attic access sealin, and completed all the other tightenings suggested by rater. This is Seier Construction's Serenity plan, interior unit, north facing with gas forced air fireplace, no basement finishing. Results of this retest after completing all the tightening that is practical to do at this stage of construction came in at 5.08 air changes per hour at 50 Pascal's pressure. While this is slightly over the stand- ard, rater suggests passing it as all the practical retro work has been completed by the builder. Jim enson, 484-3531 1 � DATE 2/27/03 CUSTOMER: Seier Construction ��� 2 �� 1469 Sailcrest Ct `� Ft COl1inS, CO 80526 _ ��� ��r Paul B 567-5236 , � BUILDING CONDITIONS : Interior Temp = 68 F Exterior Temp = 31 F Volume = 24787 Cu. Ft . Above Grade Surface Area = 0 Sq. Ft . Number of Stories = 2 Number of Occupants = 0 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By Evenson Enterprises Inc Data Points : House Pressure Fan Pressure CFM �Error Fan Configuration 31 78 1504 1.7 Ring A 37 98 1684 -0 .7 Ring A 46 128 1922 -3 . 0 Ring A 53 170 2212 1 . 7 Ring A 58 25 2322 0 . 1 Open Correlation Coefficient Flow Coefficient Exponent r = . 9937 C = 130 .24 n = 0 . 711 Results : Air Flow @ 50 Pascals : = 2101 CFM50 +/- 1 . 00 = 5 .08 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 98 . 91 Square Inches +/- 11 .4� Equivalent Leakage Area (CANADA) = 196 .51 Square Inches +/- 7 .2% Estimated Natural Infiltration (50 Pascal Flow Divided By 14 .4) = 146 CFM = 0 .35 AIR CHANGES PER HOUR