HomeMy WebLinkAbout6432 Carmichael St - Disclosures - 02/17/2003DATE 02/17/03 CUSTOMER: US HOMES 6432 Carmichael Fort Collins Co Sara's Energy Scoring 813 Oxford LN FT. COLLINS, CO 80525 (970)377-1056 BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 45 F Volume = 25500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration Ring A 58 102 1742 -1.0 48 80 1545 0.8 Ring A 41 65 1394 2.0 Ring A 33 45 1162 -0.4 Ring A 26 30 951 -3.1 Ring A 18 19 759 1.2 Ring A Correlation Coefficient Flow Coefficient Exponent = 0.730 r = .9981 C = 90.97 n Results: Air Flow @ 50 Pascals : = 1580 CFM50 +/- 0.8% = 3.72 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 70.92 Square Inches +/- 5.4% Equivalent Leakage Area (CANADA) = 143.36 Square Inches +/- 3.3% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 116 CFM = 58.2 CFM/OCCUPANT = 0.27 AIR CHANGES PER HOUR