HomeMy WebLinkAbout6514 Carmichael St - Disclosures - 02/17/2003Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 02/17/03 (970)377-1056 CUSTOMER: US Homes 6514 Carmichael Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 45 F Volume = 24000 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 56 89 1629 0.8 Ring A 50 77 1516 0.2 Ring A 44 65 1394 —0.7 Ring A 35 49 1212 —1.4 Ring A 28 38 1069 --1.0 Ring A 21 29 935 2.4 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9983 C = 155.22 n = 0.582 Results: Air Flow @ 50 Pascals : 1513 CFM50 +/— 0.6% 3.78 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 98.61 Square Inches +/— 4.1% Equivalent Leakage Area (CANADA) = 174.13 Square Inches +/— 2.5% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = Ill CFM = 55.7 CFM/OCCUPANT = 0.28 AIR CHANGES PER HOUR