HomeMy WebLinkAbout514 Peyton Dr - Special Inspections/Engineering - 09/30/2003September 30, 2003
Melody Homes
11031 Sheridan Blvd.
Westminster, Colorado 80020
Attn: Mr. Corey Weaver
Re: Exterior Perimeter Drain Observation
Ridgewood Hills 3rd Filing
514 Peyton Drive - Lot 116
Fort Collins, Colorado
Terracon Project No. 20005162
Gentlemen:
lrerracon
301 N. Howes • P.O. Box 503
Fort Collins, Colorado 80521-0503
(970) 484-0359 Fax: (970) 484-0454
A representative of Terracon observed the perimeter drain at the above referenced address on
September 11, 2003, as requested. A four -inch diameter perforated PVC pipe had been placed
around the exterior perimeter of the basement and crawl -space foundations with an impervious PVC
membrane beneath the drainage system. The drainage pipe appeared to exhibit positive drainage
toward the sump pit located within the basement area. We also observed 1 %2 inch washed gravel
placed above and below the pipe and drainage filter fabric above the gravel. The waterproof
dampening was also observed and in our opinion was uniformly applied to the exterior foundations.
In our opinion the exterior perimeter drain was constructed in general accordance with the plans and
specifications for this project.
Senior Field Technician
Copies to: (3) Addressee
David A. Richer, F
Geotechnical Eng
2
�e Departmt Manager
Arizona ■ Arkansas ■ Colorado ■ Georgia ■ Idaho ■ Illinois ■ Iowa ■ Kansas ■ Kentucky ■ Minnesota ■ Missouri
Montana ■ Nebraska ■ Nevada ■ New Mexico ■ Oklahoma ■ Tennessee ■ Texas ■ Utah ■ Wisconsin ■ Wyoming
Quality Engineering Since 1965