Loading...
HomeMy WebLinkAbout308 Peyton Dr - Special Inspections/Engineering - 11/15/2002Irerracon 301 N. Howes • P.O. Box 503 Fort Collins, Colorado 80521-0503 (970) 484-0359 Fax: (970) 484-0454 November 15, 2002 Melody Homes 11031 Sheridan Blvd. Westminster, Colorado 80020 Attn: Mr. Shawn Weiman Re: Exterior Perimeter Drain Observation Ridgewood Hills 3rd Filing 308 Peyton Drive - Lot 198 Fort Collins, Colorado Terracon Project No. 20005162 Gentlemen: A representative of Terracon observed the perimeter drain at the referenced site on November 14, 2002, as requested. A four -inch diameter perforated PVC pipe had been placed around the exterior perimeter of the basement foundation. The drainage pipe appeared to exhibit positive drainage toward the sump pit located within the basement area. We also observed 1%2 inch washed gravel placed above and below the pipe and drainage filter fabric above the gravel. The waterproof dampening was also observed and in our opinion appeared to be uniformly applied to the exterior foundations. In our opinion the exterior perimeter drain was constructed in general accordance with the plans and specifications for this project. Sincerely, TERRAC n Ripka Senior Field Technician Copies to: (3) Addressee David A. Ri& Geotechnical Manager Arizona ■ Arkansas ■ California ■ Colorado ■ Georgia ■ Idaho ■ Illinois ■ Iowa ■ Kansas ■ Kentucky ■ Minnesota ■ Missouri Montana ■ Nebraska ■ Nevada ■ New Mexico ■ Oklahoma ■ Tennessee ■ Texas ■ Utah ■ Wisconsin ■ Wyoming Consulting Engineers & Scientists Since 1965 www.terracon.com