November 15, 2002
Melody Homes
11031 Sheridan Blvd.
Westminster, Colorado 80020
Attn: Mr. Shawn Weiman
Re: Exterior Perimeter Drain Observation
Ridgewood Hills 3rd Filing
308 Peyton Drive - Lot 198
Fort Collins, Colorado
Terracon Project No. 20005162
Gentlemen:
A representative of Terracon observed the perimeter drain at the referenced site on November 14,
2002, as requested. A four -inch diameter perforated PVC pipe had been placed around the exterior
perimeter of the basement foundation. The drainage pipe appeared to exhibit positive drainage
toward the sump pit located within the basement area. We also observed 1%2 inch washed gravel
placed above and below the pipe and drainage filter fabric above the gravel. The waterproof
dampening was also observed and in our opinion appeared to be uniformly applied to the exterior
foundations.
In our opinion the exterior perimeter drain was constructed in general accordance with the plans and
specifications for this project.
Sincerely,
TERRAC
n Ripka
Senior Field Technician