Loading...
HomeMy WebLinkAbout815 Candlewood Dr - Disclosures - 10/31/2003Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 10/31/03 (970)377-1056 CUSTOMER: Kaufman and Broad 815 Candlewood Drive Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp - 35 F Volume = 19150 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = .9 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 59 91 1630 0.0 Ring A 54 84 1567 -0.6 Ring A 47 78 1511 1.0 Ring A 43 70 1432 -0.9 Ring A 34 61 1336 1.2 Ring A 27 49 1200 -0.9 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9962 C = 345.63 n = 0.380 Results: Air Flow @ 50 Pascals : 1531 CFM50 +/- 0.5% 4.80 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 166.02 Square Inches +/- ,Equivalent Leakage Area (CANADA) = 243.70 Square Inches +/- Estimated Natural Infiltration (50 Pascal Flow Divided By 12.2) = 125 CFM = 62.7 CFM/OCCUPANT = 0.39 AIR CHANGES PER HOUR 1 4.0% 2.5%