HomeMy WebLinkAbout1539 Coral Sea Ct - Disclosures - 01/30/2003 (2)Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 01/15/03 (970)377-1056 CUSTOMER: US Homes 1539 Coral Sea Ct. Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 35 F Volume = 29000 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 59 150 2088 -0.0 Ring A 52 129 1938 -0.3 Ring A 46 116 1838 1.4 Ring A 40 96 1674 0.1 Ring A 34 75 1482 -2.9 Ring A 24 55 1271 1.6 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9963 C = 203.93 n = 0.571 Results: Air Flow @ 50 Pascals : 1900 CFM50 +/- 0.7% 3.93 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 127.51 Square Inches +/- 6.0% Equivalent Leakage Area (CANADA) = 222.80 Square Inches +/- 3.7% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 140 CFM = 70.0 CFM/OCCUPANT = 0.29 AIR CHANGES PER HOUR