Loading...
HomeMy WebLinkAbout2832 Outrigger Way - Disclosures - 11/06/2003Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 11/06/03 (970)377-1056 CUSTOMER: Kaufman and Broad 2832 Outrigger Way Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 40 F Volume = 19500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = .9 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 58 72 1459 0.1 Ring A 50 66 1398 0.3 Ring A 43 60 1333 0.2 Ring A 38 54 1266 —1.2 Ring A 31 49 1206 0.2 Ring A 23 41 1104 0.4 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9983 C = 422.85 n = 0.305 Results: Air Flow @ 50 Pascals : 1393 CFM50 +/— 0.3% = 4.29 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 182.91 Square Inches +/— 2.1% Equivalent Leakage Area (CANADA) = 250.53 Square Inches +/— 1.3% Estimated Natural Infiltration (50 Pascal Flow Divided By 12.2) = 114 CFM = 57.0 CFM/OCCUPANT = 0.35 AIR CHANGES PER HOUR i