HomeMy WebLinkAbout2815 Brightwater Ct - Special Inspections/Engineering - 09/18/2002Irerracon 301 N. Howes • P.O. Box 503 Fort Collins, Colorado 80521-0503 (970) 484-0359 Fax: (970) 484-0454 September 18, 2002 KB Homes 8401 East Belleview Avenue Suite 200 Denver, Colorado 80237 Attn: Mr. Kobey Northen Re: Exterior Perimeter Drainage System Observation Richards Lake, Phase 1 Development 2815 Brightwater Court - Lot 164 Fort Collins, Colorado Terracon Project No. 20005263 Dear Mr. Northen: A representative from Terracon observed the exterior perimeter drainage system at the referenced address within the Richard's Lake Subdivision on September 16, 2002, as requested. At the time of our site visit, a 4-inch diameter, perforated PVC pipe had been placed around the exterior perimeter of the basement foundation and was observed to exhibit positive gravity flow toward a sump pit located in the lower level/basement portion of the residence. Washed gravel was observed below and above the pipe and drainage filter fabric on top of the gravel. The waterproof dampening was also observed and was uniformly applied to the exterior foundations. In our opinion the exterior drainage system was constructed in general accordance with the plans and specifications for the project. Sincerely, TERRACON J� Glenn Ripka Senior Filed Technician Copies to: (2) Addressee Richer, P.E., Geotechnical Engineer/Department Manager Arizona ■ Arkansas ■ California ■ Colorado ■ Georgia ■ Idaho ■ Illinois ■ Iowa ■ Kansas ■ Kentucky ■ Minnesota ■ Missouri Montana ■ Nebraska ■ Nevada ■ New Mexico ■ Oklahoma ■ Tennessee ■ Texas ■ Utah ■ Wisconsin ■ Wyoming Consulting Engineers & Scientists Since 1965 www.terracon.com