Loading...
HomeMy WebLinkAbout6821 Autumn Ridge Dr - Disclosures - 10/09/2003 (2)Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 10/09/03 (970)377-1056 CUSTOMER: Kaufman and Broad 6821 Autumn Ridge #2 Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 55 F Volume = 12500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 58 35 1036 -0.3 Ring A 49 27 912 -0.6 Ring A 44 24 860 1.5 Ring A 40 20 786 -0.5 Ring A 31 14 659 0.7 Ring A 20 7 467 -1.2 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9991 C = 51.73 n = 0.739 Results: Air Flow @ 50 Pascals : 931 CFM50 +/- 0.5% = 4.47 ACH50 (Air Changes Per Hour) Effective Leakage. Area (LBL) = 40.84 Square Inches +/- Equivalent Leakage Area (CANADA) = 83.27 Square Inches +/- Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) - 69 CFM = 34.3 CFM/OCCUPANT = 0.33 AIR CHANGES PER HOUR 3.7% 2.3%