HomeMy WebLinkAbout702 Prichett Ct - Special Inspections/Engineering - 08/27/2002Irerracon 301 N. Howes • P.O. Box 503 Fort Collins, Colorado 80521-0503 (970) 484-0359 Fax: (970) 484-0454 August 27, 2002 Melody Homes 11031 Sheridan Blvd. Westminster, Colorado 80020 Attn: Mr. Shawn Weiman Re: Exterior Perimeter Drain Observation Ridgewood Hills 3rd Filing — Lot 354 702 Prichett Court Foft Collins, Colorado Terracon Project No. 20005162 Gentlemen: A representative of Terracon observed the perimeter drain at the referenced site on August 26, 2002, as requested. A four -inch diameter perforated PVC pipe had been placed around the exterior perimeter of the basement foundation. The drainage pipe appeared to exhibit positive drainage toward the sump located within the basement area. We also observed 1 %2 inch washed gravel placed above and below the pipe and drainage filter fabric above the gravel. A plastic membrane was observed below the drainage system. The waterproof dampening was also observed and was uniformly applied to the exterior foundations. In our opinion the exterior perimeter drain was constructed in general accordance with the plans and specifications for this project. Sincerely, TERRACO Glenn Ripka Senior Field Technician Copies to: (3) Addressee David A. Richer, P.E. Geotechnical Engineer/Department Manager Arizona ■ Arkansas ■ California ■ Colorado ■ Georgia ■ Idaho ■ Illinois ■ Iowa ■ Kansas ■ Kentucky ■ Minnesota ■ Missouri Montana ■ Nebraska ■ Nevada ■ New Mexico ■ Oklahoma ■ Tennessee ■ Texas ■ Utah ■ Wisconsin ■ Wyoming Consulting Engineers & Scientists Since 1965 www.terracon.com