Loading...
HomeMy WebLinkAbout2815 Longboat Way - Disclosures/Final Energy - 11/19/2002Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 11/19/02 (970)377-1056 CUSTOMER: Kaufman and Broad 2815 Longboat VAV Fort Collins ,CO1 BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 45 F Volume = 23200 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 53 95 1682 0.3 Ring A 44 84 1583 -0.0 Ring A 36 73 1477 -0.7 Ring A 29 65 1394 0.3 Ring A 25 59 1329 0.1 Ring A 18 48 1200 0.1 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9996 C = 487.46 n = 0.311 Results: Air Flow @ 50 Pascals : 1647 CFM50 +/- 0.2% 4.26 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 212.77 Square Inches +/- 0.9% Equivalent Leakage Area (CANADA) = 293.15 Square Inches +/- 0.5% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 121 CFM = 60.7 CFM/OCCUPANT = 0.31 AIR CHANGES PER HOUR