HomeMy WebLinkAbout7339 Triangle Dr - Special Inspections/Engineering - 08/05/200210/21/02 MON 11:45 FAX 970 484 0454 TERRACON 1a 006 August 5, 2002 Melody Homes 11031 Sheridan Blvd. Westminster, Colorado 80020 Attn: Mr. Shawn Weiman Re: Exterior Perimeter Drain Observation Ridgewood Hills 3'd Filing 7339 Triangle Drive, Lot 172 Fort Collins, Colorado Terracon Project No. 20005162 Gentlemen: Irerracon 301 N. Howes • P.O. Box 5o3 Fort Collins. Colorado 80621-o503 (070) 484-0369 Fax; (970) 4"0454 A representative of Terracon observed the perimeter drain construction at the referenced site on August 2, 2002, as requested. A four -inch diameter perforated PVC pipe had been placed around the exterior perimeter of the basement foundation. The drainage pipe appeared to exhibit positive drainage toward the sump pump located within the basement area. We also observed 1% inch washed gravel placed above and below the pipe and drainage filter fabric above the gravel. The waterproof dampening of the foundation system was also observed and in our opinion was completed in general accordance with standard residential practices. In our opinion the exterior perimeter drain was constructed in general accordance with the plans and specifications for this project. Sincerely, TERRACON Glenn Ripka Senior Field Technician inager Copies to: (3) Addressee Arizona ■ Arkansas all California ■ Colorado ■ Georgia ■ Idaho ■ Illinois ■ Iowa ■ Kansas ■ Kentucky ■ Minneeota ■ Missouri Montana ■ Nebraska ■ Ncvada ■ New Mexico all Okialicma ■Tennessee ■ Texas as Utah ■ wi,con,^In ■ Wyoming Consulting Engineers & scientists Since 1946 www_terracon.com