HomeMy WebLinkAbout2703 Pleasant Valley Rd - Correspondence - 03/30/1998FOUNDATION II Consulting
ENGINEERING Engineers, Ltd.
March 30, 1998
Commission No.: 3929-04-04-04
Rayline Development Corporation
3600 South College Avenue #204
Fort Collins, Colorado 80525
RE: Lot 32, Siena Subdivision (2703 Pleasant Valley Road), Fort Collins, Colorado
Gentlemen:
On March 26, 1998 a representative of this firm performed visual observations at the above
referenced location. The purpose of these observations was to evaluate the crack in the foundation
wall and give recommendations for any necessary corrections.
Based on our observations, we have determined that the crack occurred during the backfilling
operations. At this time, the crack does not affect the structural integrity of the wall; however, steps
should be taken to prevent any possible additional movement in the future.
We recommend that a 2x10 be placed under the floor joists, butting against the existing sill plate.
The bottom flange of each floor joist should be nailed on each side of the web to the 2x 10. The 2x 10
should extend the full length of the cracked wall.
If you have any questions, please feel free to call.
Respectfully,
d
Charles B. Kl
Laboratory Manager
Revie by.;
Kevin attersoti, P.E.
FOUNDATION ENGINEERING, CONSULTING ENGINEERS, LTD.
CBK/jle
5110 Granite Street . Loveland, Colorado 80538 • (970) 663-0138 • Fax (970) 663-1660
515 Main Street, Suite C • Longmont, Colorado 80501 • (303) 702-0661