Loading...
HomeMy WebLinkAbout2643 Blackstone Ct - Disclosures/Final Energy - 01/05/2000Jan 05 00 05:22p SRRR (970) 2GG - 1009 p.2 SARA'S ENERGY SCORING 2115 WATER BLOSSOM LANE DATE FT. COLLINS CO 80526 01/05/00 (970) 266-1009 CUSTOMER: Al Breicht 2643 Black Stone Ft. Collins Co BUILDING CONDITIONS: Interior.Temp = 65 F Exterior Temp = 55 F Volume � 34500 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM Error Fan Configuration 54 188 2388 1.5 Ring A 48 164 2232 -0.4 Ring A 41 140 2064 -1.7 Ring A 31 114 1864 -0.4 Ring A 22 86 1622 -0.2 Ring A 14 61 1368 1.4 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9976 C = 455.27 n = 0.412 Results: Air Flow @ 50 Pascals : 2279 CFM50 +/- 0.706 3.96 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 228.39 Square Inches +/- 3.30 Equivalent Leakage Area (CANADA) = 345.00 Square Inches +/- 2.016 Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 168 CFM = 84.0 CFM/OCCUPANT = 0.29 AIR CHANGES PER HOUR