Loading...
HomeMy WebLinkAbout3839 Celtic Ln - Disclosures - 09/16/2002 (2)Sara's Energy Scoring 813 Oxford LN DATE FT. COLLINS, CO 80525 09/16/02 (970)377-1056 CUSTOMER: Kaufman and Broad 3839 Celtic Ln Fort Collins ,CO BUILDING CONDITIONS: Interior Temp = 68 F Exterior Temp = 75 F Volume = 19050 Cu. Ft. Above Grade Surface Area = 0 Sq. Ft. Number of Stories = 2 Number of Occupants = 2 Wind Shield Factor = .9 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: House Pressure Fan Pressure CFM %Error Fan Configuration 58 74 1530 2.6 Ring A 53 63 1413 -1.8 Ring A 47 56 1333 -2.8 Ring A 35 48 1235 1.3 Ring A 26 37 1086 0.3 Ring A 21 31 995 0.1 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9898 C = 295.26 n = 0.399 Results: Air Flow @ 50 Pascals = 1405 CFM50 +/- 1.1� 4.43 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) - 145.50 Square Inches +/- '6.8% Equivalent Leakage Area (CANADA) = 217.20 Square Inches +/- 4.2% Estimated Natural Infiltration (50 Pascal Flow Divided By 12.2) = 115 CFM = 57.5 CFM/OCCUPANT = 0.36 AIR CHANGES PER HOUR