Loading...
HomeMy WebLinkAbout2624 Shadow Ct - Correspondence - 04/02/1998 (2)April 2, 1998 Keigan Construction 4037 Moss Creek Drive Fort Collins, Colorado 80526 RE: 2624 Shadow Court Fort Collins, Colorado Project No. 20986054 Gentlemen 1 rerracon 301 N. Howes • P.O. Box 503 Fart Collins. Colorado 80521-0503 (970)484-0359 Fax: (970) 484-0454 As requested we have sized a beam to support second floor and roof load over a new window box addition at the referenced site. Based on the imposed loads and the approximate 9 foot span it is recommended a (2)-1 3/4 x 9 1/2" LVL beam be used. The beam should bear on a 3-2x4 trimmer each end. Solid blocking should be provided beneath the trimmers to the foundation. If you have any questions, please contact us Si ere ly, v�S;+S11li iR111/ L Gary Weeks, P.E. . Stru ural Engineer���"'•,a Arizona ■ Arkansas ■ Colorado ■ Idaho ■ Illinois ■ Iowa ■ Kansas ■ Minnesota ■ Missouri ■ Montana Nebraska ■ Nevada ■ New Mexico ■ North Dakota ■ Oklahoma ■ Tennessee ■ Texas ■ Utah ■ Wisconsin ■ Wyoming Quality Engineering Since 1965