Loading...
HomeMy WebLinkAbout708 Prichett Ct - Special Inspections/Engineering - 02/26/2002February 26, 2002 Melody Homes 11031 Sheridan Blvd. Westminster, Colorado 80020 Attn: Mr. Shawn Weiman Re: Exterior Perimeter Drain Observation Ridgewood Hills —3rd Filing 708 Prichett Court Lot 353 Fort Collins, Colorado Terracon Project No. 20005162 Mr. Weiman: A representative of Terracon observed the exterior referenced site on February 21 , 2002, as requested. Irerracon 301 N. Howes • P.O. Box 503 Fort Collins, Colorado 80521-0503 (970)484-0359 Fax: (970) 484-0454 perimeter drain construction at the A.four-inch diameter perforated PVC pipe had been placed around the exterior perimeter of the basement foundation. The drainage pipe appeared to exhibit positive drainage toward the sump located within the basement area. We also observed 11/2 - 3/4 inch washed aggregate placed above and below the pipe. The waterproof dampening of the foundation system was also observed and in our opinion was completed in general accordance with standard residential practices. In our opinion the exterior perimeter drain was constructed in general accordance with the plans and specifications for this project. Sincere, TE N ichard Hoskinson ICBO Inspector Copies to: (6) Addressee Reviewed David A. Ri84 Geotechnical oQe. F. ia�y ,.FO nt Manager Arizona ■ Arkansas ■ Colorado ■ Georgia ■ Idaho ■ Illinois ■ Iowa ■ Kansas ■ Kentucky ■ Minnesota ■ Missouri Montana ■ Nebraska ■ Nevada ■ New Mexico ■ Oklahoma ■ Tennessee ■ Texas ■ Utah ■ Wisconsin ■ Wyoming Quality Engineering Since 1965