HomeMy WebLinkAbout2300 Snow Mesa Ct - Miscellaneous - 01/01/2000Fort Collins residential energy code V96
Mechanical systems disclosure form /,._
Job address:
General contractor:
Mechanical contractor:
Space healing system
Location
Fuel
Tvpe
Manufacturer
Model #
Input capacity
kBtuh or kW
AFUE or
I HSPF
BASEMENT
GAS
F A
Space cooling system
Location
Fuel
Tvpe
I Manufacturer
Model #
Input capacity
kBtuh or kW
( SEER
GAS
F/A
ff
I
Water heating system...
Location
Fuel
Tvpe
I Manufacturer
I Model #
Input capacity
I kBtuh or kW
( Energy
Factor
( Storage
volume
Certification
UWe certify that the above -listed equipment was installed in the building at the above locations in conformance with the
current requirements of the City of Fort Collins Residential Energy Code and Mechanical Code, and that it was installed in
accordance with manufacturer's instructions. I/We certify that any ductwork has been installed in conformance with
the current requirements of the City of Fort Collins Residential Energy Code and Mechanical Code.
Certified by: ROBERT R MLLLER Phone: (970) 223-8873
Business firm710COLORADO AIR, INC .Date:
Address:1823 E HARMONY RD Signature: -;]z _
i
Instructions
-
This disclosure form is to be signed by the mechanical contractor or representative of the general contractor.
Please type or print, except for the signature.
If there are multiple systems serving any function, make multiple entries to describe them.
One copy of this form shall be provided to the Building and Zoning Department at final inspection.
One copy of this form shall be provided to the homebuyer.
Fort Collins residential energy code 7/96 O
Insulation disclosure form
Job Address: 2300
General Contractor: Ktrtu
Insulation Contractor: Thermal Concepts Insulation
P.O. Box 270066
Fort Collins, CO 80522
970-223-7090
I/We certify that the above listed insulation in the building at the above locations in conformance with the current requirements of the City of Fort Collins
Residential Energy Code, and that it was installed in accordance with the applicable "Insulation Installation Guidelines" published by the City of Fort Collins.
Certified by: Thermal Concepts Insulation Phone: 970-223-7090
Business firm: Thermal Concepts Insulation Date:
Address: 6617 S. College Ave. Signature:
This disclosure for is to be signed by the insulation contractor or representative of the general contractor.
Please type or print, except for the signature.
If components vary, make multiple entries to describe them.
One copy of this form shall be provided to the Building and Zoninq Department of final inspection.
One copy of this form shall be provided to the home buyer.
SARA'S ENERGY SCORING
2115 WATER BLOSSOM LANE
DATE FT. COLLINS CO 80526
12/23/99 (970) 266-1009
CUSTOMER: KEM HOMES
2300 Snow Mesa
Ft. Collins Co
UILDING CONDITIONS:
Interior Temp = 60 F
Volume = 34550 Cu. Ft.
Number of Stories = 2
Wind Shield Factor = 1
HOUSE TEST : Depressurized
Fan Model = 3
Performed By SARA
Data Points:
Exterior Temp = 35 F
Above Grade Surface Area = 0 Sq. Ft.
Number of Occupants = 2
House Pressure
Fan Pressure
CFM
'-.Error
Fan Configuration
55
126
1930
1.0
Ring A
46
100
1721
-1.0
Ring A
34
74
1483
0.1
Ring A
29
60
1337
-1.9
Ring A
24
51
1234
0.0
Ring A
18
39
1080
1.9
Ring A
Correlation Coefficient
Flow Coefficient
Exponent
r = .9982
C =
230.27
n = 0.528
Results:
Air Flow @ 50 Pascals :
1817 CFM50 +/- 0.7%
3.15 ACH50 (Air Changes Per Hour)
Effective Leakage Area (LBL) = 135.72 Square Inches +/- 3.6%
Equivalent Leakage Area (CANADA) = 228.08 Square Inches +/- 2.1%
Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6)
= 134 CFM
= 66.9 CFM/OCCUPANT
= 0.23 AIR CHANGES PER HOUR