Loading...
HomeMy WebLinkAbout2300 Snow Mesa Ct - Miscellaneous - 01/01/2000Fort Collins residential energy code V96 Mechanical systems disclosure form /,._ Job address: General contractor: Mechanical contractor: Space healing system Location Fuel Tvpe Manufacturer Model # Input capacity kBtuh or kW AFUE or I HSPF BASEMENT GAS F A Space cooling system Location Fuel Tvpe I Manufacturer Model # Input capacity kBtuh or kW ( SEER GAS F/A ff I Water heating system... Location Fuel Tvpe I Manufacturer I Model # Input capacity I kBtuh or kW ( Energy Factor ( Storage volume Certification UWe certify that the above -listed equipment was installed in the building at the above locations in conformance with the current requirements of the City of Fort Collins Residential Energy Code and Mechanical Code, and that it was installed in accordance with manufacturer's instructions. I/We certify that any ductwork has been installed in conformance with the current requirements of the City of Fort Collins Residential Energy Code and Mechanical Code. Certified by: ROBERT R MLLLER Phone: (970) 223-8873 Business firm710COLORADO AIR, INC .Date: Address:1823 E HARMONY RD Signature: -;]z _ i Instructions - This disclosure form is to be signed by the mechanical contractor or representative of the general contractor. Please type or print, except for the signature. If there are multiple systems serving any function, make multiple entries to describe them. One copy of this form shall be provided to the Building and Zoning Department at final inspection. One copy of this form shall be provided to the homebuyer. Fort Collins residential energy code 7/96 O Insulation disclosure form Job Address: 2300 General Contractor: Ktrtu Insulation Contractor: Thermal Concepts Insulation P.O. Box 270066 Fort Collins, CO 80522 970-223-7090 I/We certify that the above listed insulation in the building at the above locations in conformance with the current requirements of the City of Fort Collins Residential Energy Code, and that it was installed in accordance with the applicable "Insulation Installation Guidelines" published by the City of Fort Collins. Certified by: Thermal Concepts Insulation Phone: 970-223-7090 Business firm: Thermal Concepts Insulation Date: Address: 6617 S. College Ave. Signature: This disclosure for is to be signed by the insulation contractor or representative of the general contractor. Please type or print, except for the signature. If components vary, make multiple entries to describe them. One copy of this form shall be provided to the Building and Zoninq Department of final inspection. One copy of this form shall be provided to the home buyer. SARA'S ENERGY SCORING 2115 WATER BLOSSOM LANE DATE FT. COLLINS CO 80526 12/23/99 (970) 266-1009 CUSTOMER: KEM HOMES 2300 Snow Mesa Ft. Collins Co UILDING CONDITIONS: Interior Temp = 60 F Volume = 34550 Cu. Ft. Number of Stories = 2 Wind Shield Factor = 1 HOUSE TEST : Depressurized Fan Model = 3 Performed By SARA Data Points: Exterior Temp = 35 F Above Grade Surface Area = 0 Sq. Ft. Number of Occupants = 2 House Pressure Fan Pressure CFM '-.Error Fan Configuration 55 126 1930 1.0 Ring A 46 100 1721 -1.0 Ring A 34 74 1483 0.1 Ring A 29 60 1337 -1.9 Ring A 24 51 1234 0.0 Ring A 18 39 1080 1.9 Ring A Correlation Coefficient Flow Coefficient Exponent r = .9982 C = 230.27 n = 0.528 Results: Air Flow @ 50 Pascals : 1817 CFM50 +/- 0.7% 3.15 ACH50 (Air Changes Per Hour) Effective Leakage Area (LBL) = 135.72 Square Inches +/- 3.6% Equivalent Leakage Area (CANADA) = 228.08 Square Inches +/- 2.1% Estimated Natural Infiltration (50 Pascal Flow Divided By 13.6) = 134 CFM = 66.9 CFM/OCCUPANT = 0.23 AIR CHANGES PER HOUR